ARM: rmobile: Fix broken reset code on Porter

The 'reset' command did not work on Porter because the reset code
was accessing the wrong PMIC address over broken I2C bus driver.
Replace the code with DM-aware code and fix up the PMIC address.
This makes the 'reset' command work again.

Signed-off-by: Marek Vasut <marek.vasut+renesas@gmail.com>
Cc: Nobuhiro Iwamatsu <iwamatsu@nigauri.org>
This commit is contained in:
Marek Vasut 2018-02-17 02:16:48 +01:00 committed by Marek Vasut
parent a6e50da0d5
commit 25f6dc8955

View File

@ -116,12 +116,25 @@ const struct rmobile_sysinfo sysinfo = {
void reset_cpu(ulong addr)
{
u8 val;
struct udevice *dev;
const u8 pmic_bus = 6;
const u8 pmic_addr = 0x5a;
u8 data;
int ret;
i2c_set_bus_num(2); /* PowerIC connected to ch2 */
i2c_read(CONFIG_SYS_I2C_POWERIC_ADDR, 0x13, 1, &val, 1);
val |= 0x02;
i2c_write(CONFIG_SYS_I2C_POWERIC_ADDR, 0x13, 1, &val, 1);
ret = i2c_get_chip_for_busnum(pmic_bus, pmic_addr, 1, &dev);
if (ret)
hang();
ret = dm_i2c_read(dev, 0x13, &data, 1);
if (ret)
hang();
data |= BIT(1);
ret = dm_i2c_write(dev, 0x13, &data, 1);
if (ret)
hang();
}
#ifdef CONFIG_SPL_BUILD