serial: ns16550: Use old baud rate divisor for flushing if not given
If baud_divisor is not set (i.e. == -1), we should use the baud divisor already in use for flushing the xmit register. If we don't flush the xmit register, then SPL will hang. Signed-off-by: Patrik Dahlström <risca@dalakolonin.se>
This commit is contained in:
parent
b1b147f2b8
commit
1c16606aac
@ -171,6 +171,13 @@ void NS16550_init(NS16550_t com_port, int baud_divisor)
|
||||
== UART_LSR_THRE) {
|
||||
if (baud_divisor != -1)
|
||||
NS16550_setbrg(com_port, baud_divisor);
|
||||
else {
|
||||
// Re-use old baud rate divisor to flush transmit reg.
|
||||
const int dll = serial_in(&com_port->dll);
|
||||
const int dlm = serial_in(&com_port->dlm);
|
||||
const int divisor = dll | (dlm << 8);
|
||||
NS16550_setbrg(com_port, divisor);
|
||||
}
|
||||
serial_out(0, &com_port->mdr1);
|
||||
}
|
||||
#endif
|
||||
|