forked from Minki/linux
beb1b6bbf2
Driver for the TI TMP102. The TI TMP102 is similar to the LM75. It differs from the LM75 by having a 16-bit conf register and the temp registers have a minimum resolution of 12 bits; the extended conf register can select 13-bit resolution (which this driver does) and also change the update rate (which this driver currently doesn't use). [JD: Fix tmp102_exit tag, must be __exit, not __init.] Signed-off-by: Steven King <sfking@fdwdc.com> Signed-off-by: Jean Delvare <khali@linux-fr.org>
28 lines
952 B
Plaintext
28 lines
952 B
Plaintext
Kernel driver tmp102
|
|
====================
|
|
|
|
Supported chips:
|
|
* Texas Instruments TMP102
|
|
Prefix: 'tmp102'
|
|
Addresses scanned: I2C 0x48 0x49 0x4a 0x4b
|
|
Datasheet: http://focus.ti.com/docs/prod/folders/print/tmp102.html
|
|
|
|
Author:
|
|
Steven King <sfking@fdwdc.com>
|
|
|
|
Description
|
|
-----------
|
|
|
|
The Texas Instruments TMP102 implements one temperature sensor. Limits can be
|
|
set through the Overtemperature Shutdown register and Hysteresis register. The
|
|
sensor is accurate to 0.5 degrees over the range of -25 to +85 C, and to 1.0
|
|
degrees from -40 to +125 C. Resolution of the sensor is 0.0625 degree. The
|
|
operating temperature has a minimum of -55 C and a maximum of +150 C.
|
|
|
|
The TMP102 has a programmable update rate that can select between 8, 4, 1, and
|
|
0.5 Hz. (Currently the driver only supports the default of 4 Hz).
|
|
|
|
The driver provides the common sysfs-interface for temperatures (see
|
|
/Documentation/hwmon/sysfs-interface under Temperatures).
|
|
|