*LM87 hwmon sensor.
|
|
|
|
Required properties:
|
|
- compatible: Should be
|
|
"ti,lm87"
|
|
|
|
- reg: I2C address
|
|
|
|
optional properties:
|
|
- has-temp3: This configures pins 18 and 19 to be used as a second
|
|
remote temperature sensing channel. By default the pins
|
|
are configured as voltage input pins in0 and in5.
|
|
|
|
- has-in6: When set, pin 5 is configured to be used as voltage input
|
|
in6. Otherwise the pin is set as FAN1 input.
|
|
|
|
- has-in7: When set, pin 6 is configured to be used as voltage input
|
|
in7. Otherwise the pin is set as FAN2 input.
|
|
|
|
- vcc-supply: a Phandle for the regulator supplying power, can be
|
|
cofigured to measure 5.0V power supply. Default is 3.3V.
|
|
|
|
Example:
|
|
|
|
lm87@2e {
|
|
compatible = "ti,lm87";
|
|
reg = <0x2e>;
|
|
has-temp3;
|
|
vcc-supply = <®_5v0>;
|
|
};
|