Timers on Versatile Express mainboard are used as system clock/event
sources. Driver assumes that they are clocked with 1MHz signal.
Old V2M firmware apparently configured it by default, but on newer
boards one can observe that "sleep 1" command takes over 30 seconds
to finish, as the timers are fed with 32kHz instead...
This patch performs required magic and also removes code clearing
timer's control registers, as exactly the same operations are
performed by the timer driver few jiffies later.
Signed-off-by: Pawel Moll <pawel.moll@arm.com>
Tested-by: Will Deacon <will.deacon@arm.com>
Signed-off-by: Russell King <rmk+kernel@arm.linux.org.uk>