Since commit528222d853("media: rc: harmonize infrared durations to microseconds"), the calculation of the chk period is wrong. As a result, all reported IR will have incorrect timings. Now that the calculations are done in microseconds rather than nanoseconds, we can fold the calculations in a simpler form with less rounding error. Tested-by: Frank Wunderlich <frank-w@public-files.de> Fixes:528222d853("media: rc: harmonize infrared durations to microseconds") Signed-off-by: Sean Young <sean@mess.org> Signed-off-by: Mauro Carvalho Chehab <mchehab+huawei@kernel.org>