It is necessary to clear MC13892_SWITCHERS0_SWxHI bit when set voltage to the
voltage range from 1100000 to 1375000. Leaving MC13892_SWITCHERS0_SWxHI bit
untouched may result in wrong voltage setting.
For example, currently switch voltage from 1400000 to 1300000 will set the
voltage to 1800000 because the HI bit is still set.
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Signed-off-by: Mark Brown <broonie@sirena.org.uk>
It's safe to call regulator_unregister() with NULL, thus remove the NULL test
before regulator_unregister() calls.
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Signed-off-by: Mark Brown <broonie@sirena.org.uk>
Patch adds device tree probe support for mc13783-regulator driver.
Signed-off-by: Alexander Shiyan <shc_work@mail.ru>
Signed-off-by: Mark Brown <broonie@sirena.org.uk>
This patch adds a warning about incorrect regulators instead of
printing the names of non-information message about the wrong amount.
Signed-off-by: Alexander Shiyan <shc_work@mail.ru>
Signed-off-by: Mark Brown <broonie@sirena.org.uk>
Ensure to unregister all regulators before return error in probe().
The regulator register order depends on the regulator ID pass to
ab3100_regulator_register() function. Thus we need to scan ab3100_regulator_desc
and find the index of successfully registered regulators, or alternatively just
call ab3100_regulators_remove() to unregister all registered regulators.
Since current code uses a static ab3100_regulators table, explicitly set
reg->rdev = NULL after regulator_unregister() call to ensure calling
ab3100_regulators_remove() in the unwind path always work.
Also move ab3100_regulators_remove() to avoid forward declaration.
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
All regulators have ascendant voltage list in this driver.
Use regulator_map_voltage_ascend for them.
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
All regulators have ascendant voltage list in this driver.
Use regulator_map_voltage_ascend for them.
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
All regulators have ascendant voltage list in this driver.
Use regulator_map_voltage_ascend for them.
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Both mc13892_sw1 and mc13892_sw voltage table have ascendant voltage list.
Use regulator_map_voltage_ascend for them.
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
All regulators have ascendant voltage list in this driver.
Use regulator_map_voltage_ascend for them.
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
tps65020 ldo1 and ldo2 vsel tables are identical, merge them.
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
All regulators have ascendant voltage list in this driver.
Use regulator_map_voltage_ascend for them.
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
This implements device tree support for the AB3100 regulators
driver. The initial settings are moved out of platform data
and into the driver for the device tree case, as it appears
that there is no way to supply this as AUXDATA for an I2C
device. The style and bindings are heavily inspired by
Lee Jones' style for AB8500.
Signed-off-by: Linus Walleij <linus.walleij@linaro.org>
Acked-by: Lee Jones <lee.jones@linaro.org>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
This refactors the AB3100 regulator probe to use regulator IDs
and pass this to a separate registration function. This works
much smoother when migrating to device tree, as we can use a
match table with this regulator ID encoded in the .driver_data.
Signed-off-by: Linus Walleij <linus.walleij@linaro.org>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Current code overrides control1 variable when setting ramp delay bits.
Fix it by just setting ramp_delay bits.
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Acked-by: Laxman Dewangan <ldewangan@nvidia.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
All regulators have ascendant voltage list in this driver.
Thus use regulator_map_voltage_ascend is more efficient than the default
regulator_map_voltage_iterate.
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
All regulators have ascendant voltage list in this driver.
Some regulators have more than 200 supported voltages.
e.g.
For TPS65910_REG_VDD1 and TPS65910_REG_VDD2:
n_voltages = VDD1_2_NUM_VOLT_FINE * VDD1_2_NUM_VOLT_COARSE
= 73 * 3
= 219
Thus it worth converting to regulator_map_voltage_ascend rather than use
default regulator_map_voltage_iterate.
For consistent, convert all regulators to regulator_map_voltage_ascend.
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
All regulators have ascendant voltage list in this driver.
Thus use regulator_map_voltage_ascend is more efficient than the default
regulator_map_voltage_iterate.
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Acked-by: Marek Szyprowski <m.szyprowski@samsung.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
All regulators have ascendant voltage list in this driver.
Thus use regulator_map_voltage_ascend is more efficient than the default
regulator_map_voltage_iterate.
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Acked-by: Marek Szyprowski <m.szyprowski@samsung.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Datasheet says:
Time Step (TSTEP) selection, when changing the output voltage, the new value is
reached through successive voltage steps (if not bypassed). The equivalent
programmable slew rate of the output voltage is:
TSTEP[1:0]: 00 Jump (no slope control)
TSTEP[1:0]: 01 10mV/us
TSTEP[1:0]: 10 5mV/us (default)
TSTEP[1:0]: 11 2.5mV/us
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Acked-by: Laxman Dewangan <ldewangan@nvidia.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
The ctrl_addr setting for SMPS10 is missed, thus palmas_smps_init() read/write
wrong register for SMPS10 in current code. Fix it.
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Acked-by: Laxman Dewangan <ldewangan@nvidia.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
SMPS3 and SMPS7 do not have tstep_addr setting, so current code actually
writes 0 to smps12_ctl (offset is 0) register when set_ramp_delay callback
is called for SMPS3 and SMPS7.
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Acked-by: Laxman Dewangan <ldewangan@nvidia.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
When SMPS45 is set to off and LDO8 tracking is enabled, the output voltage can
be set from 0.45 to 1.65 V. Thus set min_uV to be 450000.
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Acked-by: Laxman Dewangan <ldewangan@nvidia.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
The voltage_shift can be calculated from voltage_mask.
Let's remove voltage_shift fied from struct ab8500_regulator_info, this change
can prevent missing voltage_shift setting issue.
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Acked-by: Bengt Jonsson <bengt.g.jonsson@stericsson.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
The voltage_shift field of struct expand_register is not used now, remove it.
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Acked-by: Bengt Jonsson <bengt.g.jonsson@stericsson.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
The Palma device like TPS65913 have the mode mask which is also
used for enable/disable the rails. The mode bits are defined as
00: OFF
01: AUTO
10: ECO
11: Forced PWM
and modes are set accordingly as
REGULATOR_MODE_NORMAL: AUTO
REGULATOR_MODE_IDLE: ECO
REGULATOR_MODE_FAST: PWM
Two issue observed:
1. If client calls following sequence:
regulator_enable(),
regulator_set_mode(FAST),
regulator_disable()
and again the regulator_enable() then the mode is reset
to NORMAL inplace of keeping the mode as FAST.
Fixing this by storing the current mode configured by client
and restoring modes when enable() is called after disable().
2. In following sequence, the regulator get enabled:
regulator_disable()
regulator_set_mode(FAST),
Fixing this by updating new mode in register only if it is
enabled.
Signed-off-by: Laxman Dewangan <ldewangan@nvidia.com>
Acked-by: Graeme Gregory <gg@slimlogic.co.uk>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Currently Palma regulator driver support the ramp delay
through rail specific platform data.
As regulator framework support the configuration of ramp
delay through regulator constraint, using the framework
method and removing the platform specific data approach.
Signed-off-by: Laxman Dewangan <ldewangan@nvidia.com>
Acked-by: Graeme Gregory <gg@slimlogic.co.uk>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
A lot of regulator hardware has ascendant voltage list.
This patch adds regulator_map_voltage_ascend() and export it.
Drivers that have ascendant voltage list can use this as their map_voltage()
operation, this is more efficient than default regulator_map_voltage_iterate()
function.
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
When setting voltage for AB8540_LDO_AUX3, current code only updates one of
info->voltage_reg and info->expand_register registers which is wrong.
To ensure we set to correct voltage, it always needs to clear or set
expand_register.voltage_mask bit of expand_register.
The function of the expand register bit is the following (from the user manual):
0: VAUX3 output voltage is determined by Vaux3Sel bit settings in register
VldoCVaux3Sel
1: VAUX3 output voltage is set to 3.05V regardless of Vaux3Sel settings in
register VldoCVaux3Sel (VldoCVaux3Sel is the register at 0x0421)
So when going to 3.05V, set the expand register bit.
When leaving 3.05V for another voltage, set the target voltage before clearing
the expand register bit.
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Acked-by: Bengt Jonsson <bengt.g.jonsson@stericsson.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Both enable() and disable() functions have only one caller, thus remove them.
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Acked-by: Bengt Jonsson <bengt.g.jonsson@stericsson.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>