[why]
DC does not correct account for the fact that DPP DTO is double buffered while DPP ref is not.
This means that when DPP ref clock is lowered when it's "safe to lower", the DPP blocks that need
an increased divider will temporarily have actual DPP clock drop below minimum while DTO
double buffering takes effect. This results in temporary underflow.
[how]
To fix this, DPP clock cannot be programmed atomically, but rather be broken up into the DTO and the
ref. Each has a separate "safe to lower" logic. When doing "prepare" the ref and dividers may only increase.
When doing "optimize", both may decrease. It is guaranteed that we won't exceed max DPP clock because
we do not use dividers larger than 1.
Signed-off-by: Jun Lei <Jun.Lei@amd.com>
Reviewed-by: Eric Yang <eric.yang2@amd.com>
Acked-by: Leo Li <sunpeng.li@amd.com>
Signed-off-by: Alex Deucher <alexander.deucher@amd.com>
[why]
"reference clock" is a very overloaded variable in DC and causes confusion
as there are multiple sources of reference clock, which may be different values
incorrect input values to DML will cause DCHUB to be programmed improperly
and lead to hard to debug underflow issues
[how]
instead of using ref clock everywhere, specify WHICH ref clock:
- xtalin
- dccg refclk
- dchub refclk
these are all distinct values which may not be equal
Signed-off-by: Jun Lei <Jun.Lei@amd.com>
Reviewed-by: Yongqiang Sun <yongqiang.sun@amd.com>
Acked-by: David Francis <David.Francis@amd.com>
Acked-by: Leo Li <sunpeng.li@amd.com>
Signed-off-by: Alex Deucher <alexander.deucher@amd.com>