CONFIG_HOTPLUG is going away as an option. As a result, the __dev*
markings need to be removed.
This change removes the use of __devinit, __devexit_p, __devinitdata,
__devinitconst, and __devexit from these drivers.
Based on patches originally written by Bill Pemberton, but redone by me
in order to handle some of the coding style issues better, by hand.
Cc: Bill Pemberton <wfp5p@virginia.edu>
Cc: Liam Girdwood <lrg@ti.com>
Cc: Mark Brown <broonie@opensource.wolfsonmicro.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
CONFIG_HOTPLUG is going away as an option so __devexit is no
longer needed.
Signed-off-by: Bill Pemberton <wfp5p@virginia.edu>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
CONFIG_HOTPLUG is going away as an option so __devinit is no longer
needed.
Signed-off-by: Bill Pemberton <wfp5p@virginia.edu>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
CONFIG_HOTPLUG is going away as an option so __devexit_p is no longer
needed.
Signed-off-by: Bill Pemberton <wfp5p@virginia.edu>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Fixes this build error:
drivers/regulator/twl-regulator.c: In function 'twlreg_probe':
drivers/regulator/twl-regulator.c:1229:3: error: implicit declaration of function 'kfree' [-Werror=implicit-function-declaration]
Also added string.h for kmemdup().
Signed-off-by: Stephen Rothwell <sfr@canb.auug.org.au>
Acked-by: Arnd Bergmann <arnd@arndb.de>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
I currently carry the series to make of_device_id->data const in the
arm-soc tree, which fixes a number of issues, but leaves one new
compiler warning about the twl-regulator driver:
drivers/regulator/twl-regulator.c: In function 'twlreg_probe':
drivers/regulator/twl-regulator.c:1130:8: warning: assignment discards 'const'
qualifier from pointer target type [enabled by default]
drivers/regulator/twl-regulator.c:1139:9: warning: assignment discards 'const'
qualifier from pointer target type [enabled by default]
The warning indicates that the driver takes a static table with
initialization data for each regulator, modifies the data in place
and passes a pointer to that structure to the regulator_register
function. This is probably ok because a system contains only one
instance of each regulator, but it's still bad style because any
driver should be written to support multiple instances of the same
hardware.
This patch changes the code to dynamically allocate the memory
we pass to the regulator core so the table can be constant.
Signed-off-by: Arnd Bergmann <arnd@arndb.de>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
This is not required after commit f7df20ec
"regulator: core: Use list_voltage() to read single voltage regulators"
Signed-off-by: Axel Lin <axel.lin@gmail.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
The voltage selection logic is supposed to find the samllest voltage falls
within specified range. When using equation to calculate vsel, we need to
ensure the requested min_uV meet the range of using the equation.
Otherwise we may select a voltage that is out of specified range.
For example, in the case vsel = 62 means select voltage of 2100000uV.
What we want is to ensure the requested min_uV <= 2100000 rather than checking
max_uV >= 2100000. And this also means in the case min_uV > 2100000, vsel = 62
does not meet the request.
Also calling twl6030smps_list_voltage() for all cases to ensure the selected
voltage still in bounds.
Signed-off-by: Axel Lin <axel.lin@gmail.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
It seems commit 2098e95ce9 (regulator: twl:
adapt twl-regulator driver to dt) accidentally deleted VINTANA1. Also
the same commit defines VINTANA2 twice with TWL4030_ADJUSTABLE_LDO and
TWL4030_FIXED_LDO. This patch changes the fixed one to be VINTANA1.
I noticed this when auditing my N900 boot logs. I could not notice any
change in device behaviour, though, except that the boot logs are now
like before:
...
[ 0.282928] VDAC: 1800 mV normal standby
[ 0.284027] VCSI: 1800 mV normal standby
[ 0.285400] VINTANA1: 1500 mV normal standby
[ 0.286865] VINTANA2: 2750 mV normal standby
[ 0.288208] VINTDIG: 1500 mV normal standby
[ 0.289978] VSDI_CSI: 1800 mV normal standby
...
Signed-off-by: Aaro Koskinen <aaro.koskinen@iki.fi>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Cc: stable@vger.kernel.org
According to the datasheet, the voltage for twl6030ldo_ops is not linear for
all cases. Linear mapping is only for the selection code from
00000001 to 00011000.
Table 9. LDO Output Voltage Selection Code
CODE VOUT(V) COD VOUT(V) CODE VOUT(V) CODE VOUT(V)
00000000 0 00001000 1.7 00010000 2.5 00011000 3.3
00000001 1.0 00001001 1.8 00010001 2.6 00011001 Reserved
00000010 1.1 00001010 1.9 00010010 2.7 00011010 Reserved
00000011 1.2 00001011 2.0 00010011 2.8 00011011 Reserved
00000100 1.3 00001100 2.1 00010100 2.9 00011100 Reserved
00000101 1.4 00001101 2.2 00010101 3.0 00011101 Reserved
00000110 1.5 00001110 2.3 00010110 3.1 00011110 Reserved
00000111 1.6 00001111 2.4 00010111 3.2 00011111 2.75
This patch implements the list_voltage callback based on above table.
Signed-off-by: Axel Lin <axel.lin@gmail.com>
Tested-by: Rajendra Nayak <rnayak@ti.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
In twl6030ldo_set_voltage, current code use below formula to calculate vsel:
vsel = (min_uV/1000 - 1000)/100 + 1;
This is worng because when min_uV is 1000000 uV, vsel is 1.
It should be 0 in this case.
Fix it by change the equation to: (This equation is common for linear mapping)
vsel = DIV_ROUND_UP(min_uV - rdev->desc->min_uV, rdev->desc->uV_step);
In twl6030ldo_get_voltage, current code use below formula to calculate voltage:
mV = 1000mv + 100mv * (vsel - 1)
This is worng because when vsel is 0, mV is 900mV. Note the min_uV is 1000mV.
Fix it by change the equation to: (This equation is common for linear mapping)
return rdev->desc->min_uV + vsel * rdev->desc->uV_step;
Signed-off-by: Axel Lin <axel.lin@gmail.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Due to the lack of a generic clock API we'd had the 32kHz clock in the
regulator driver but this is definitely a Linux-specific thing and now
we have a clock API hopefully the code can be moved elsewhere. Try to
avoid getting DTs deployed relying on the 32kHz clock by removing it
from the bindings, grep seems to tell me it's not currently used anyway.
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
The regulators in the twl4030 can provide some voltage settings
that are not offically supported.
These settings are disabled by default, but can be enabled with
CONFIG_TWL4030_ALLOW_UNSUPPORTED=y
However
- that config variable is not mentioned in any Kconfig so cannot
be used, and
- a global setting is clumsy - a per regulator setting would be
better.
So define a new 'feature' flag that a board file can set to enable
these unsupported volatages for boards which need them.
This flag cannot (yet) be set using device-tree.
Signed-off-by: NeilBrown <neilb@suse.de>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
All the drivers that need delay for the regulator voltage output voltage to
stabilize after being enabled or after being set to a new value has been
converted to implement enable_time and set_voltage_time_sel callbacks.
Then regulator core will take care of the necessary delay.
For the drivers that don't need the delay, don't need to include linux/delay.h.
This patch removes the unneeded include of linux/delay.h in regulator drivers.
Signed-off-by: Axel Lin <axel.lin@gmail.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Since the twlreg_grp helper function is there, use it.
Signed-off-by: Axel Lin <axel.lin@gmail.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Let regulator core do the necessary delay for us.
Signed-off-by: Axel Lin <axel.lin@gmail.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
commit 268a1 "regulator: twl-regulator: Use DIV_ROUND_UP at appropriate places"
introduced an off-by-one bug for setting vsel.
The linear calculation code in twl6030smps_list_voltage() does subtract index
by 1 so we need the vsel++ after DIV_ROUND_UP.
The original code use this trick to differentiate if we are going to set the
voltage to 0 or the voltage falls within the linear calculation range.
Signed-off-by: Axel Lin <axel.lin@gmail.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
This patch makes the code easier to read.
Also add checking the case when no desc id is matched. This is required because
if no desc id is matched, the poiner info is pointed to twl_of_match[i].data
which may be not NULL. Checking info is NULL or not latter does not catch the
error.
Signed-off-by: Axel Lin <axel.lin@gmail.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Rather than adding new arguments to regulator_register() every time we
want to add a new bit of dynamic information at runtime change the function
to take these via a struct. By doing this we avoid needing to do further
changes like the recent addition of device tree support which required each
regulator driver to be updated to take an additional parameter.
The regulator_desc which should (mostly) be static data is still passed
separately as most drivers are able to configure this statically at build
time.
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
V1V8 supply most common use is to provide VIO for the system.
V2V1 supply is used on SDP4430/PandaBoards to provide 2.1V to
twl6040, and also as an input to VCXIO_IN, VDAC_IN of twl6030.
Also update the bindings documentation with the new compatible
property for these additional LDOs.
Signed-off-by: Peter Ujfalusi <peter.ujfalusi@ti.com>
Signed-off-by: Rajendra Nayak <rnayak@ti.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Modify the twl regulator driver to extract the regulator_init_data from
device tree when passed, instead of getting it through platform_data
structures (on non-DT builds)
Also add documentation for TWL regulator specific bindings.
Signed-off-by: Rajendra Nayak <rnayak@ti.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
vdd1 and vdd2 are now common regulators for twl4030 and twl6030. Also
added vdd3 as a new regulator for twl6030. twl6030 vdd1...vdd3 smps
regulator voltages can only be controlled through the smartreflex
voltage channel, thus the support for the voltage_get and set is
minimal and requires external controller.
Signed-off-by: Tero Kristo <t-kristo@ti.com>
Signed-off-by: Rajendra Nayak <rnayak@ti.com>
Acked-by: Samuel Ortiz <sameo@linux.intel.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
This is needed for SMPS regulators, which use the OMAP voltage
processor for voltage get/set functions instead of the normal I2C
channel. For this purpose, regulator_init_data->driver_data contents
are expanded, it is now a struct which contains function pointers
for the set/get voltage operations, a data pointer for these, and
the previously used features bitmask.
Signed-off-by: Tero Kristo <t-kristo@ti.com>
Acked-by: Samuel Ortiz <sameo@linux.intel.com> [for the MFD part]
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
The voltage selection logic for the twl6030 smps fails if
min:max is such that min < 1300mV and max > 1300mV although
this is in valid range for a regulator e.g. [x, 1350] where
x < 1300.
Fixing the voltage selection logic such that first it will
check for min_uV for a range and then calculated value will
be checked against max_uV.
Signed-off-by: Laxman Dewangan <ldewangan@nvidia.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
SMPS regulator voltage control differs from the one of the LDO ones.
Current TWL code was using LDO regulator ops for controlling the SMPS
regulators, which fails. This was fixed fixed by adding separate
regulator type which uses correct logic and calculations for the
voltage levels.
Signed-off-by: Tero Kristo <t-kristo@ti.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Cc: stable@kernel.org
With device tree support for regulators, its needed that the
regulator_dev->dev device has the right of_node attached.
To be able to do this add an additional parameter to the
regulator_register() api, wherein the dt-adapted driver can
then pass this additional info onto the regulator core.
Signed-off-by: Rajendra Nayak <rnayak@ti.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
RES_ID is only used in 4030, to send PBM singular message to control
the state of dedicated resources. In 6030, we don't have concept of PBM,
hence removing the definition of RES_ID (num) from macros.
Signed-off-by: Ambresh K <ambresh@ti.com>
Acked-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Signed-off-by: Liam Girdwood <lrg@slimlogic.co.uk>
The n_voltages initializer for the TWL6030_ADJUSTABLE_LDO macro is
off by one, causing the the highest supported voltage to be
unreachable. Setting the machine constraints to only allow the
highest voltage causes errors:
machine_constraints_voltage: VAUX3_6030: unsupportable voltage constraints
twl_reg twl_reg.39: can't register VAUX3_6030, -22
twl_reg: probe of twl_reg.39 failed with error -22
This patch fixes the off by one error. Tested by setting
VAUX3_6030 to 3.3V.
Signed-off-by: Colin Cross <ccross@android.com>
Acked-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Signed-off-by: Liam Girdwood <lrg@slimlogic.co.uk>
Adding support for the twl6025. Major difference in the twl6025 is the
group functionality has been removed from the chip so this affects how
regulators are enabled and disabled.
The names of the regulators also changed.
The DCDCs of the 6025 are software controllable as well.
Since V1
Use the features variable passed via platform data instead of calling
global function.
Change the very switch like if statements to be a more readable
switch statement.
Since V2
twl6025 doesn't use remap so remove it from the macros.
Since V3
enable/disable functions for 4030/6030 were seperated upstream so rebase
on top of this. Change DCDC reference to SMPS as this is used in TRM.
Change list_voltage slightly to have less code.
Signed-off-by: Graeme Gregory <gg@slimlogic.co.uk>
Acked-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Signed-off-by: Liam Girdwood <lrg@slimlogic.co.uk>
TWL6030: regulator is disabled via VREG_STATE
TWL4030: regulator is disabled via VREG_GRP
Since there is nothing common, split twlreg_enable similar to other regulator_ops
Signed-off-by: Balaji T K <balajitk@ti.com>
Acked-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Signed-off-by: Liam Girdwood <lrg@slimlogic.co.uk>
TWL6030: regulator is enabled via VREG_STATE
TWL4030: regulator is enabled via VREG_GRP
Since there is nothing common, split twlreg_enable similar to other regulator_ops
Signed-off-by: Balaji T K <balajitk@ti.com>
Acked-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Signed-off-by: Liam Girdwood <lrg@slimlogic.co.uk>
Current set_mode logic does not support 6030. The logic for 4030 is
not reusable for 6030 as the mode setting for 6030 now uses the new
CFG_STATE register. We hence rename the old get_status as being
specific to 4030.
Signed-off-by: Nishanth Menon <nm@ti.com>
Signed-off-by: Saquib Herman <saquib@ti.com>
Acked-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Signed-off-by: Liam Girdwood <lrg@vega.(none)>
Current get_status logic does not support 6030 get_status.
The logic for 4030 is not reusable for 6030 as the status
check for 6030 now depends on the new CFG_STATE register.
We hence rename the old get_status as being specific to
4030 and remove the redundant check for the same.
Signed-off-by: Nishanth Menon <nm@ti.com>
Signed-off-by: Saquib Herman <saquib@ti.com>
Acked-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Signed-off-by: Liam Girdwood <lrg@vega.(none)>
With TWL6030, it is not enough to ensure that the regulator is the
group of P1 group (CPU/Linux), but we need to check the state as far
as APP is concerned as well.
Split the current is_enabled to 6030 and 4030 specific ones. This
split impacts few macros and variables as well, but sets up the
stage for further fixes to set_mode and get_status in subsequent
patches.
Signed-off-by: Nishanth Menon <nm@ti.com>
Signed-off-by: Saquib Herman <saquib@ti.com>
Acked-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Signed-off-by: Liam Girdwood <lrg@vega.(none)>
TWL6030 does not have remap register. The current implementation
causes value of remap to be written to state register, accidentally
causing the regulators which are probed to be switched on as well.
This is wrong as regulators should be controllable based on calls
to enable/disable for TWL regulator framework. Further, the values
initialized make no sense as well. We hence remove this from the
initalizers and also write to remap register only if the TWL
is 4030.
Signed-off-by: Nishanth Menon <nm@ti.com>
Signed-off-by: Saquib Herman <saquib@ti.com>
Acked-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Signed-off-by: Liam Girdwood <lrg@vega.(none)>
TWL6030 requires an additional register write to CFG_STATE register
to explicitly state that the regulator is in a certain state. Merely
associating the regulator with the group is not enough. Add the
required register field definitions and fix the handling for
TWL6030 enable/disable.
Signed-off-by: Nishanth Menon <nm@ti.com>
Signed-off-by: Saquib Herman <saquib@ti.com>
Acked-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Signed-off-by: Liam Girdwood <lrg@vega.(none)>
In OMAP4 Blaze and Panda, 32KHz clock to WLAN is supplied from Phoenix
TWL6030. The 32KHz clock state (ON/OFF) is configured in
CLK32KG_CFG_[GRP, TRANS, STATE] register. This follows the same register
programming model as other regulators in TWL6030. So add CLK32KG as pseudo
regulator.
Signed-off-by: Balaji T K <balajitk@ti.com>
Acked-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Signed-off-by: Samuel Ortiz <sameo@linux.intel.com>
Change the interface used by set_voltage() to report the selected value
to the regulator core in terms of a selector used by list_voltage().
This allows the regulator core to know the voltage that was chosen
without having to do an explict get_voltage(), which would be much more
expensive as it will generally access hardware.
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Signed-off-by: Liam Girdwood <lrg@slimlogic.co.uk>
The Singular Message is 16 bits:
DEV_GRP[15:13] MT[12] RES_ID[11:4] RES_STATE[3:0]
Current implementation return immedially after sucessfuly write MSB part.
To properly set mode, we need to write the complete message ( MSB and LSB ).
In twl.h, now we have defines for PM Master module register offsets,
use it instead of hard coded 0x15/0x16.
Use "message & 0xff" to ensure we send correct value for LSB.
Signed-off-by: Axel Lin <axel.lin@gmail.com>
Acked-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Tested-by: Lesly Arackal Manuel <leslyam@ti.com>
Signed-off-by: Liam Girdwood <lrg@slimlogic.co.uk>
All twl6030 regulators can be programmed from 1.0v to 3.3v
with 100mV steps.
The below formula can be used to calculate the vsel values
to be programmed in the VREG_VOLTAGE registers.
Voltage(in mV) = 1000mv + 100mv * (vsel - 1)
Ex: if vsel = 0x9, mV = 1000 + 100 * (9 -1) = 1800mV.
This patch removes all existing VSEL tables for twl6030 adjustable
regulators and just uses the formula directly for vsel calculations
after verifing they fall in the allowed range.
Signed-off-by: Rajendra Nayak <rnayak@ti.com>
Cc: Liam Girdwood <lrg@slimlogic.co.uk>
Cc: Samuel Ortiz <sameo@linux.intel.com>
Cc: Mark Brown <broonie@opensource.wolfsonmicro.com>
Acked-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Signed-off-by: Liam Girdwood <lrg@slimlogic.co.uk>