forked from Minki/linux
dt-bindings: add documentation for s3c2410 clock controller
Describe the clock controller of s3c2410, s3c2440 and s3c2442. Signed-off-by: Heiko Stuebner <heiko@sntech.de> Acked-by: Tomasz Figa <t.figa@samsung.com> Signed-off-by: Kukjin Kim <kgene.kim@samsung.com>
This commit is contained in:
parent
51cb128987
commit
f11cadd582
@ -0,0 +1,50 @@
|
||||
* Samsung S3C2410 Clock Controller
|
||||
|
||||
The S3C2410 clock controller generates and supplies clock to various controllers
|
||||
within the SoC. The clock binding described here is applicable to the s3c2410,
|
||||
s3c2440 and s3c2442 SoCs in the s3c24x family.
|
||||
|
||||
Required Properties:
|
||||
|
||||
- compatible: should be one of the following.
|
||||
- "samsung,s3c2410-clock" - controller compatible with S3C2410 SoC.
|
||||
- "samsung,s3c2440-clock" - controller compatible with S3C2440 SoC.
|
||||
- "samsung,s3c2442-clock" - controller compatible with S3C2442 SoC.
|
||||
- reg: physical base address of the controller and length of memory mapped
|
||||
region.
|
||||
- #clock-cells: should be 1.
|
||||
|
||||
Each clock is assigned an identifier and client nodes can use this identifier
|
||||
to specify the clock which they consume. Some of the clocks are available only
|
||||
on a particular SoC.
|
||||
|
||||
All available clocks are defined as preprocessor macros in
|
||||
dt-bindings/clock/samsung,s3c2410-clock.h header and can be used in device
|
||||
tree sources.
|
||||
|
||||
External clocks:
|
||||
|
||||
The xti clock used as input for the plls is generated outside the SoC. It is
|
||||
expected that is are defined using standard clock bindings with a
|
||||
clock-output-names value of "xti".
|
||||
|
||||
Example: Clock controller node:
|
||||
|
||||
clocks: clock-controller@4c000000 {
|
||||
compatible = "samsung,s3c2410-clock";
|
||||
reg = <0x4c000000 0x20>;
|
||||
#clock-cells = <1>;
|
||||
};
|
||||
|
||||
Example: UART controller node that consumes the clock generated by the clock
|
||||
controller (refer to the standard clock bindings for information about
|
||||
"clocks" and "clock-names" properties):
|
||||
|
||||
serial@50004000 {
|
||||
compatible = "samsung,s3c2440-uart";
|
||||
reg = <0x50004000 0x4000>;
|
||||
interrupts = <1 23 3 4>, <1 23 4 4>;
|
||||
clock-names = "uart", "clk_uart_baud2";
|
||||
clocks = <&clocks PCLK_UART0>, <&clocks PCLK_UART0>;
|
||||
status = "disabled";
|
||||
};
|
Loading…