forked from Minki/linux
ARM: davinci: dm644x: fix out range signal for ED
Fix the video clock setting when custom timings are used with pclock <= 27MHz. Existing video clock selection uses PLL2 mode which results in a 54MHz clock whereas using the MXI mode results in a 27MHz clock (which is the one actually desired). This bug affects the Enhanced Definition (ED) support on DM644x. Without this patch, out-range signals errors are were observed on the TV when viewing ED. An out-of-range signal is often caused when the field rate is above the rate that the television will handle. Signed-off-by: Lad, Prabhakar <prabhakar.lad@ti.com> Signed-off-by: Manjunath Hadli <manjunath.hadli@ti.com> Cc: Sekhar Nori <nsekhar@ti.com> [nsekhar@ti.com: reword commit message based on on-list discussion] Signed-off-by: Sekhar Nori <nsekhar@ti.com>
This commit is contained in:
parent
f4a75d2eb7
commit
e37212aa5d
@ -713,8 +713,7 @@ static int dm644x_venc_setup_clock(enum vpbe_enc_timings_type type,
|
||||
break;
|
||||
case VPBE_ENC_CUSTOM_TIMINGS:
|
||||
if (pclock <= 27000000) {
|
||||
v |= DM644X_VPSS_MUXSEL_PLL2_MODE |
|
||||
DM644X_VPSS_DACCLKEN;
|
||||
v |= DM644X_VPSS_DACCLKEN;
|
||||
writel(v, DAVINCI_SYSMOD_VIRT(SYSMOD_VPSS_CLKCTL));
|
||||
} else {
|
||||
/*
|
||||
|
Loading…