ASoC: pcm179x: Support continuous rates
According to the PCM179x data sheets sampling frequencies between 10 kHz and 200 kHz are supported. Specify support in the driver. Tested with PCM1791A. References: http://www.ti.com/lit/ds/symlink/pcm1791a.pdf http://www.ti.com/lit/ds/symlink/pcm1792a.pdf http://www.ti.com/lit/ds/symlink/pcm1795.pdf http://www.ti.com/lit/ds/symlink/pcm1796.pdf Signed-off-by: Jacob Siverskog <jacob@teenage.engineering> Reviewed-by: Johan Hovold <johan@kernel.org> Acked-by: Michael Trimarchi <michael@amarulasolutions.com> Signed-off-by: Mark Brown <broonie@kernel.org>
This commit is contained in:
parent
70e3e56e6c
commit
e0236f541e
@ -187,7 +187,9 @@ static struct snd_soc_dai_driver pcm179x_dai = {
|
|||||||
.stream_name = "Playback",
|
.stream_name = "Playback",
|
||||||
.channels_min = 2,
|
.channels_min = 2,
|
||||||
.channels_max = 2,
|
.channels_max = 2,
|
||||||
.rates = PCM1792A_RATES,
|
.rates = SNDRV_PCM_RATE_CONTINUOUS,
|
||||||
|
.rate_min = 10000,
|
||||||
|
.rate_max = 200000,
|
||||||
.formats = PCM1792A_FORMATS, },
|
.formats = PCM1792A_FORMATS, },
|
||||||
.ops = &pcm179x_dai_ops,
|
.ops = &pcm179x_dai_ops,
|
||||||
};
|
};
|
||||||
|
@ -17,10 +17,6 @@
|
|||||||
#ifndef __PCM179X_H__
|
#ifndef __PCM179X_H__
|
||||||
#define __PCM179X_H__
|
#define __PCM179X_H__
|
||||||
|
|
||||||
#define PCM1792A_RATES (SNDRV_PCM_RATE_44100 | SNDRV_PCM_RATE_8000_48000 | \
|
|
||||||
SNDRV_PCM_RATE_88200 | SNDRV_PCM_RATE_96000 | \
|
|
||||||
SNDRV_PCM_RATE_192000)
|
|
||||||
|
|
||||||
#define PCM1792A_FORMATS (SNDRV_PCM_FMTBIT_S32_LE | SNDRV_PCM_FMTBIT_S24_LE | \
|
#define PCM1792A_FORMATS (SNDRV_PCM_FMTBIT_S32_LE | SNDRV_PCM_FMTBIT_S24_LE | \
|
||||||
SNDRV_PCM_FMTBIT_S16_LE)
|
SNDRV_PCM_FMTBIT_S16_LE)
|
||||||
|
|
||||||
|