ASoC: rt286: Restore default in probe

RT286 can't do register reset. If the hardware power is still existing
in power off, rt286 will keep the register settings. So, we need to
restore the default register value in probe to make sure the cache value
is the same as the real register value.

Signed-off-by: Bard Liao <bardliao@realtek.com>
Signed-off-by: Mark Brown <broonie@kernel.org>
This commit is contained in:
Bard Liao 2015-04-09 11:20:32 +08:00 committed by Mark Brown
parent 143526ee94
commit d53d59ecad

View File

@ -1250,6 +1250,14 @@ static int rt286_i2c_probe(struct i2c_client *i2c,
rt286->i2c = i2c;
i2c_set_clientdata(i2c, rt286);
/* restore codec default */
for (i = 0; i < INDEX_CACHE_SIZE; i++)
regmap_write(rt286->regmap, rt286->index_cache[i].reg,
rt286->index_cache[i].def);
for (i = 0; i < ARRAY_SIZE(rt286_reg); i++)
regmap_write(rt286->regmap, rt286_reg[i].reg,
rt286_reg[i].def);
if (pdata)
rt286->pdata = *pdata;