mod_devicetable: fix PHY module format

When a PHY is probed, if the top bit is set, we end up requesting a
module with the string "mdio:-10101110000000100101000101010001" -
the top bit is printed to a signed -1 value. This leads to the module
not being loaded.

Fix the module format string and the macro generating the values for
it to ensure that we only print unsigned types and the top bit is
always 0/1. We correctly end up with
"mdio:10101110000000100101000101010001".

Fixes: 8626d3b432 ("phylib: Support phy module autoloading")
Reviewed-by: Andrew Lunn <andrew@lunn.ch>
Signed-off-by: Russell King <rmk+kernel@armlinux.org.uk>
Reviewed-by: Florian Fainelli <f.fainelli@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
This commit is contained in:
Russell King 2019-12-19 23:24:47 +00:00 committed by David S. Miller
parent 4c8dc00503
commit d2ed49cf6c

View File

@ -587,9 +587,9 @@ struct platform_device_id {
#define MDIO_NAME_SIZE 32
#define MDIO_MODULE_PREFIX "mdio:"
#define MDIO_ID_FMT "%d%d%d%d%d%d%d%d%d%d%d%d%d%d%d%d%d%d%d%d%d%d%d%d%d%d%d%d%d%d%d%d"
#define MDIO_ID_FMT "%u%u%u%u%u%u%u%u%u%u%u%u%u%u%u%u%u%u%u%u%u%u%u%u%u%u%u%u%u%u%u%u"
#define MDIO_ID_ARGS(_id) \
(_id)>>31, ((_id)>>30) & 1, ((_id)>>29) & 1, ((_id)>>28) & 1, \
((_id)>>31) & 1, ((_id)>>30) & 1, ((_id)>>29) & 1, ((_id)>>28) & 1, \
((_id)>>27) & 1, ((_id)>>26) & 1, ((_id)>>25) & 1, ((_id)>>24) & 1, \
((_id)>>23) & 1, ((_id)>>22) & 1, ((_id)>>21) & 1, ((_id)>>20) & 1, \
((_id)>>19) & 1, ((_id)>>18) & 1, ((_id)>>17) & 1, ((_id)>>16) & 1, \