forked from Minki/linux
s390: fix test_fp_ctl inline assembly contraints
The test_fp_ctl function is used to test if a given value is a valid
floating-point control. The inline assembly in test_fp_ctl uses an
incorrect constraint for the 'orig_fpc' variable. If the compiler
chooses the same register for 'fpc' and 'orig_fpc' the test_fp_ctl()
function always returns true. This allows user space to trigger
kernel oopses with invalid floating-point control values on the
signal stack.
This problem has been introduced with git commit 4725c86055
"s390: fix save and restore of the floating-point-control register"
Cc: stable@vger.kernel.org # v3.13+
Reviewed-by: Heiko Carstens <heiko.carstens@de.ibm.com>
Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com>
This commit is contained in:
parent
5419447e21
commit
bcf4dd5f9e
@ -22,7 +22,7 @@ static inline int test_fp_ctl(u32 fpc)
|
||||
" la %0,0\n"
|
||||
"1:\n"
|
||||
EX_TABLE(0b,1b)
|
||||
: "=d" (rc), "=d" (orig_fpc)
|
||||
: "=d" (rc), "=&d" (orig_fpc)
|
||||
: "d" (fpc), "0" (-EINVAL));
|
||||
return rc;
|
||||
}
|
||||
|