forked from Minki/linux
b44: use fixed PHY device if we do not find any
The ADM6996L switch and some Broadcom switches with two MII interfaces like the BCM5325F connected to two MACs on the SoC, used on some routers do not return a valid value when reading the PHY id register and Linux thinks there is no PHY at all, but that is wrong. This patch registers a fixed phy in the arch code and then searches it when there is no other phy in the Ethernet driver code. Signed-off-by: Hauke Mehrtens <hauke@hauke-m.de> Signed-off-by: David S. Miller <davem@davemloft.net>
This commit is contained in:
parent
656a7c2b12
commit
b04138b335
@ -28,6 +28,9 @@
|
||||
|
||||
#include <linux/export.h>
|
||||
#include <linux/types.h>
|
||||
#include <linux/ethtool.h>
|
||||
#include <linux/phy.h>
|
||||
#include <linux/phy_fixed.h>
|
||||
#include <linux/ssb/ssb.h>
|
||||
#include <linux/ssb/ssb_embedded.h>
|
||||
#include <linux/bcma/bcma_soc.h>
|
||||
@ -225,6 +228,12 @@ void __init plat_mem_setup(void)
|
||||
bcm47xx_board_detect();
|
||||
}
|
||||
|
||||
static struct fixed_phy_status bcm47xx_fixed_phy_status __initdata = {
|
||||
.link = 1,
|
||||
.speed = SPEED_100,
|
||||
.duplex = DUPLEX_FULL,
|
||||
};
|
||||
|
||||
static int __init bcm47xx_register_bus_complete(void)
|
||||
{
|
||||
switch (bcm47xx_bus_type) {
|
||||
@ -239,6 +248,7 @@ static int __init bcm47xx_register_bus_complete(void)
|
||||
break;
|
||||
#endif
|
||||
}
|
||||
fixed_phy_add(PHY_POLL, 0, &bcm47xx_fixed_phy_status);
|
||||
return 0;
|
||||
}
|
||||
device_initcall(bcm47xx_register_bus_complete);
|
||||
|
@ -2233,6 +2233,7 @@ static int b44_register_phy_one(struct b44 *bp)
|
||||
struct ssb_device *sdev = bp->sdev;
|
||||
struct phy_device *phydev;
|
||||
char bus_id[MII_BUS_ID_SIZE + 3];
|
||||
struct ssb_sprom *sprom = &sdev->bus->sprom;
|
||||
int err;
|
||||
|
||||
mii_bus = mdiobus_alloc();
|
||||
@ -2266,7 +2267,20 @@ static int b44_register_phy_one(struct b44 *bp)
|
||||
goto err_out_mdiobus_irq;
|
||||
}
|
||||
|
||||
snprintf(bus_id, sizeof(bus_id), PHY_ID_FMT, mii_bus->id, bp->phy_addr);
|
||||
if (!bp->mii_bus->phy_map[bp->phy_addr] &&
|
||||
(sprom->boardflags_lo & (B44_BOARDFLAG_ROBO | B44_BOARDFLAG_ADM))) {
|
||||
|
||||
dev_info(sdev->dev,
|
||||
"could not find PHY at %i, use fixed one\n",
|
||||
bp->phy_addr);
|
||||
|
||||
bp->phy_addr = 0;
|
||||
snprintf(bus_id, sizeof(bus_id), PHY_ID_FMT, "fixed-0",
|
||||
bp->phy_addr);
|
||||
} else {
|
||||
snprintf(bus_id, sizeof(bus_id), PHY_ID_FMT, mii_bus->id,
|
||||
bp->phy_addr);
|
||||
}
|
||||
|
||||
phydev = phy_connect(bp->dev, bus_id, &b44_adjust_link,
|
||||
PHY_INTERFACE_MODE_MII);
|
||||
|
@ -345,6 +345,9 @@ B44_STAT_REG_DECLARE
|
||||
struct u64_stats_sync syncp;
|
||||
};
|
||||
|
||||
#define B44_BOARDFLAG_ROBO 0x0010 /* Board has robo switch */
|
||||
#define B44_BOARDFLAG_ADM 0x0080 /* Board has ADMtek switch */
|
||||
|
||||
struct ssb_device;
|
||||
|
||||
struct b44 {
|
||||
|
Loading…
Reference in New Issue
Block a user