iio: Add support for humidity sensors
There are already humidity sensors in the hwmon subsystem, so we use their unit (milli percent) here as well. Signed-off-by: Harald Geyer <harald@ccbib.org> Signed-off-by: Jonathan Cameron <jic23@kernel.org>
This commit is contained in:
parent
6f93910eba
commit
ac216aa290
@ -197,6 +197,19 @@ Description:
|
||||
Raw pressure measurement from channel Y. Units after
|
||||
application of scale and offset are kilopascal.
|
||||
|
||||
What: /sys/bus/iio/devices/iio:deviceX/in_humidityrelative_raw
|
||||
KernelVersion: 3.14
|
||||
Contact: linux-iio@vger.kernel.org
|
||||
Description:
|
||||
Raw humidity measurement of air. Units after application of
|
||||
scale and offset are milli percent.
|
||||
|
||||
What: /sys/bus/iio/devices/iio:deviceX/in_humidityrelative_input
|
||||
KernelVersion: 3.14
|
||||
Contact: linux-iio@vger.kernel.org
|
||||
Description:
|
||||
Scaled humidity measurement in milli percent.
|
||||
|
||||
What: /sys/bus/iio/devices/iio:deviceX/in_accel_offset
|
||||
What: /sys/bus/iio/devices/iio:deviceX/in_accel_x_offset
|
||||
What: /sys/bus/iio/devices/iio:deviceX/in_accel_y_offset
|
||||
|
@ -69,6 +69,7 @@ static const char * const iio_chan_type_name_spec[] = {
|
||||
[IIO_ALTVOLTAGE] = "altvoltage",
|
||||
[IIO_CCT] = "cct",
|
||||
[IIO_PRESSURE] = "pressure",
|
||||
[IIO_HUMIDITYRELATIVE] = "humidityrelative",
|
||||
};
|
||||
|
||||
static const char * const iio_modifier_names[] = {
|
||||
|
@ -29,6 +29,7 @@ enum iio_chan_type {
|
||||
IIO_ALTVOLTAGE,
|
||||
IIO_CCT,
|
||||
IIO_PRESSURE,
|
||||
IIO_HUMIDITYRELATIVE,
|
||||
};
|
||||
|
||||