hwmon: (sht3x) wait predefined limits loading complete before access

An sht3x sensor include limits register which contains temperature
and humidity limit values. After a reset, pre-defined values are loaded
into that register. During the probe function, the driver reads the
limits register. However, if the reads are made too early, and the bus
is clocked at high frequencies (e.g. 100 kHz or more), the loading could be
not completed and the sensor returns a NACK which causes the probe to fail.
A delay of at least 500 us before the first read solves this issue.

Signed-off-by: Emiliano Ingrassia <ingrassia@epigenesys.com>
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
This commit is contained in:
Emiliano Ingrassia 2018-01-12 21:42:28 +01:00 committed by Guenter Roeck
parent b007640649
commit abe6c3b06f

View File

@ -732,6 +732,13 @@ static int sht3x_probe(struct i2c_client *client,
mutex_init(&data->i2c_lock);
mutex_init(&data->data_lock);
/*
* An attempt to read limits register too early
* causes a NACK response from the chip.
* Waiting for an empirical delay of 500 us solves the issue.
*/
usleep_range(500, 600);
ret = limits_update(data);
if (ret)
return ret;