forked from Minki/linux
serial8250: Mark console as CON_ANYTIME
While trying to debug a cpu-hotplug issue I noticed printk() stopped working once the cpu got marked offline, since the 8250 serial console doesn't have any per-cpu resources the CON_ANYTIME bit is the safe and documented way to make it work again. Signed-off-by: Peter Zijlstra <a.p.zijlstra@chello.nl> Signed-off-by: Greg Kroah-Hartman <gregkh@suse.de>
This commit is contained in:
parent
e53beacd23
commit
a80c49dbb6
@ -2872,7 +2872,7 @@ static struct console serial8250_console = {
|
||||
.device = uart_console_device,
|
||||
.setup = serial8250_console_setup,
|
||||
.early_setup = serial8250_console_early_setup,
|
||||
.flags = CON_PRINTBUFFER,
|
||||
.flags = CON_PRINTBUFFER | CON_ANYTIME,
|
||||
.index = -1,
|
||||
.data = &serial8250_reg,
|
||||
};
|
||||
|
Loading…
Reference in New Issue
Block a user