ASoC: TWL4030: Fix for digital loopback gain range
When the gain is configured using dB value it was not possible to use -24dB since the loopback got muted instead of -24dB. Signed-off-by: Peter Ujfalusi <peter.ujfalusi@nokia.com> Acked-by: Mark Brown <broonie@opensource.wolfsomicro.com> Signed-off-by: Liam Girdwood <lrg@slimlogic.co.uk>
This commit is contained in:
parent
66b47fdb85
commit
8b0d31532e
@ -540,10 +540,11 @@ static const struct snd_kcontrol_new twl4030_dapm_abypassl2_control =
|
|||||||
static const struct snd_kcontrol_new twl4030_dapm_abypassv_control =
|
static const struct snd_kcontrol_new twl4030_dapm_abypassv_control =
|
||||||
SOC_DAPM_SINGLE("Switch", TWL4030_REG_VDL_APGA_CTL, 2, 1, 0);
|
SOC_DAPM_SINGLE("Switch", TWL4030_REG_VDL_APGA_CTL, 2, 1, 0);
|
||||||
|
|
||||||
/* Digital bypass gain, 0 mutes the bypass */
|
/* Digital bypass gain, mute instead of -30dB */
|
||||||
static const unsigned int twl4030_dapm_dbypass_tlv[] = {
|
static const unsigned int twl4030_dapm_dbypass_tlv[] = {
|
||||||
TLV_DB_RANGE_HEAD(2),
|
TLV_DB_RANGE_HEAD(3),
|
||||||
0, 3, TLV_DB_SCALE_ITEM(-2400, 0, 1),
|
0, 1, TLV_DB_SCALE_ITEM(-3000, 600, 1),
|
||||||
|
2, 3, TLV_DB_SCALE_ITEM(-2400, 0, 0),
|
||||||
4, 7, TLV_DB_SCALE_ITEM(-1800, 600, 0),
|
4, 7, TLV_DB_SCALE_ITEM(-1800, 600, 0),
|
||||||
};
|
};
|
||||||
|
|
||||||
|
Loading…
Reference in New Issue
Block a user