regulator: palmas: configure enable time for LDOs
As per datasheet (Referred TPS65913), the on-time for LDO is 500micro second. If LDO6 is in vibrator mode then the on-time is 2000us. Set the enable_time on regulator descriptor accordingly. Signed-off-by: Laxman Dewangan <ldewangan@nvidia.com> Signed-off-by: Mark Brown <broonie@linaro.org>
This commit is contained in:
parent
32b6d3f602
commit
5957e444d2
@ -1127,6 +1127,7 @@ static int palmas_regulators_probe(struct platform_device *pdev)
|
||||
pmic->desc[id].min_uV = 900000;
|
||||
pmic->desc[id].uV_step = 50000;
|
||||
pmic->desc[id].linear_min_sel = 1;
|
||||
pmic->desc[id].enable_time = 500;
|
||||
pmic->desc[id].vsel_reg =
|
||||
PALMAS_BASE_TO_REG(PALMAS_LDO_BASE,
|
||||
palmas_regs_info[id].vsel_addr);
|
||||
@ -1145,6 +1146,11 @@ static int palmas_regulators_probe(struct platform_device *pdev)
|
||||
pmic->desc[id].min_uV = 450000;
|
||||
pmic->desc[id].uV_step = 25000;
|
||||
}
|
||||
|
||||
/* LOD6 in vibrator mode will have enable time 2000us */
|
||||
if (pdata && pdata->ldo6_vibrator &&
|
||||
(id == PALMAS_REG_LDO6))
|
||||
pmic->desc[id].enable_time = 2000;
|
||||
} else {
|
||||
pmic->desc[id].n_voltages = 1;
|
||||
if (reg_init && reg_init->roof_floor)
|
||||
|
Loading…