mac80211: fix harmless station flush warning
If an interface is set down while authenticating or associating, there's a station entry that will be removed by the flushing in do_stop() and that will cause a warning. It's otherwise harmless, but avoid the warning by calling ieee80211_mgd_stop() first. Signed-off-by: Johannes Berg <johannes.berg@intel.com>
This commit is contained in:
parent
6295ca184b
commit
572078be54
@ -696,6 +696,9 @@ static void ieee80211_do_stop(struct ieee80211_sub_if_data *sdata,
|
||||
|
||||
ieee80211_roc_purge(sdata);
|
||||
|
||||
if (sdata->vif.type == NL80211_IFTYPE_STATION)
|
||||
ieee80211_mgd_stop(sdata);
|
||||
|
||||
/*
|
||||
* Remove all stations associated with this interface.
|
||||
*
|
||||
@ -783,8 +786,6 @@ static void ieee80211_do_stop(struct ieee80211_sub_if_data *sdata,
|
||||
}
|
||||
}
|
||||
spin_unlock_irqrestore(&ps->bc_buf.lock, flags);
|
||||
} else if (sdata->vif.type == NL80211_IFTYPE_STATION) {
|
||||
ieee80211_mgd_stop(sdata);
|
||||
}
|
||||
|
||||
if (going_down)
|
||||
|