V4L/DVB (7004): cx23885: Ensure HVR1800 TDA8295A is reset fully on module load
Failure to do this means that a full system reboot is required if the part hangs. Signed-off-by: Steven Toth <stoth@hauppauge.com> Signed-off-by: Mauro Carvalho Chehab <mchehab@infradead.org>
This commit is contained in:
parent
0ac5881aef
commit
5206d6ec36
@ -268,7 +268,13 @@ void cx23885_gpio_setup(struct cx23885_dev *dev)
|
|||||||
/* GPIO-15-18 cx23417 READY, CS, RD, WR */
|
/* GPIO-15-18 cx23417 READY, CS, RD, WR */
|
||||||
/* GPIO-19 IR_RX */
|
/* GPIO-19 IR_RX */
|
||||||
|
|
||||||
cx_set(GP0_IO, 0x00040004); /* Bring the tuner out of reset */
|
/* Force the TDA8295A into reset and back */
|
||||||
|
cx_set(GP0_IO, 0x00040004);
|
||||||
|
mdelay(20);
|
||||||
|
cx_clear(GP0_IO, 0x00000004);
|
||||||
|
mdelay(20);
|
||||||
|
cx_set(GP0_IO, 0x00040004);
|
||||||
|
mdelay(20);
|
||||||
break;
|
break;
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
|