of: Fix premature bootconsole disable with 'stdout-path'
Support for devicetree serial consoles via 'stdout-path' causes bootconsoles to be disabled when the vt dummy console loads, since there is no preferred console (the preferred console is not added until the device is probed). Ensure there is at least a preferred console, even if never matched. Requires: "console: Fix console name size mismatch" Cc: Andrew Morton <akpm@linux-foundation.org> Signed-off-by: Peter Hurley <peter@hurleysoftware.com> Signed-off-by: Rob Herring <robh@kernel.org>
This commit is contained in:
parent
2c192699a7
commit
2fa645cb27
@ -1886,8 +1886,10 @@ void of_alias_scan(void * (*dt_alloc)(u64 size, u64 align))
|
||||
name = of_get_property(of_chosen, "linux,stdout-path", NULL);
|
||||
if (IS_ENABLED(CONFIG_PPC) && !name)
|
||||
name = of_get_property(of_aliases, "stdout", NULL);
|
||||
if (name)
|
||||
if (name) {
|
||||
of_stdout = of_find_node_opts_by_path(name, &of_stdout_options);
|
||||
add_preferred_console("stdout-path", 0, NULL);
|
||||
}
|
||||
}
|
||||
|
||||
if (!of_aliases)
|
||||
|