forked from Minki/linux
stmmac: Add support for SIMATIC IOT2000 platform
The IOT2000 is industrial controller platform, derived from the Intel Galileo Gen2 board. The variant IOT2020 comes with one LAN port, the IOT2040 has two of them. They can be told apart based on the board asset tag in the DMI table. Based on patch by Sascha Weisenberger. Signed-off-by: Jan Kiszka <jan.kiszka@siemens.com> Signed-off-by: Sascha Weisenberger <sascha.weisenberger@siemens.com> Reviewed-by: Andy Shevchenko <andy.shevchenko@gmail.com> Signed-off-by: David S. Miller <davem@davemloft.net>
This commit is contained in:
parent
412b65d15a
commit
212c7fd614
@ -32,6 +32,7 @@
|
||||
*/
|
||||
struct stmmac_pci_dmi_data {
|
||||
const char *name;
|
||||
const char *asset_tag;
|
||||
unsigned int func;
|
||||
int phy_addr;
|
||||
};
|
||||
@ -46,6 +47,7 @@ struct stmmac_pci_info {
|
||||
static int stmmac_pci_find_phy_addr(struct stmmac_pci_info *info)
|
||||
{
|
||||
const char *name = dmi_get_system_info(DMI_BOARD_NAME);
|
||||
const char *asset_tag = dmi_get_system_info(DMI_BOARD_ASSET_TAG);
|
||||
unsigned int func = PCI_FUNC(info->pdev->devfn);
|
||||
struct stmmac_pci_dmi_data *dmi;
|
||||
|
||||
@ -57,8 +59,12 @@ static int stmmac_pci_find_phy_addr(struct stmmac_pci_info *info)
|
||||
return 1;
|
||||
|
||||
for (dmi = info->dmi; dmi->name && *dmi->name; dmi++) {
|
||||
if (!strcmp(dmi->name, name) && dmi->func == func)
|
||||
if (!strcmp(dmi->name, name) && dmi->func == func) {
|
||||
/* If asset tag is provided, match on it as well. */
|
||||
if (dmi->asset_tag && strcmp(dmi->asset_tag, asset_tag))
|
||||
continue;
|
||||
return dmi->phy_addr;
|
||||
}
|
||||
}
|
||||
|
||||
return -ENODEV;
|
||||
@ -153,6 +159,24 @@ static struct stmmac_pci_dmi_data quark_pci_dmi_data[] = {
|
||||
.func = 6,
|
||||
.phy_addr = 1,
|
||||
},
|
||||
{
|
||||
.name = "SIMATIC IOT2000",
|
||||
.asset_tag = "6ES7647-0AA00-0YA2",
|
||||
.func = 6,
|
||||
.phy_addr = 1,
|
||||
},
|
||||
{
|
||||
.name = "SIMATIC IOT2000",
|
||||
.asset_tag = "6ES7647-0AA00-1YA2",
|
||||
.func = 6,
|
||||
.phy_addr = 1,
|
||||
},
|
||||
{
|
||||
.name = "SIMATIC IOT2000",
|
||||
.asset_tag = "6ES7647-0AA00-1YA2",
|
||||
.func = 7,
|
||||
.phy_addr = 1,
|
||||
},
|
||||
{}
|
||||
};
|
||||
|
||||
|