be2net: Remove code that stops further access to BE NIC based on UE bits
On certain platforms, BE hardware could falsely indicate UE. For BE family of NICs, do not set hw_error based on the UE bits. If there was a real fatal error, the corresponding h/w block will automatically go offline and stop traffic. Signed-off-by: Ajit Khaparde <ajit.khaparde@emulex.com> Signed-off-by: David S. Miller <davem@davemloft.net>
This commit is contained in:
parent
0f79657984
commit
1451ae6ef8
@ -2129,8 +2129,11 @@ void be_detect_error(struct be_adapter *adapter)
|
||||
ue_hi = (ue_hi & ~ue_hi_mask);
|
||||
}
|
||||
|
||||
if (ue_lo || ue_hi ||
|
||||
sliport_status & SLIPORT_STATUS_ERR_MASK) {
|
||||
/* On certain platforms BE hardware can indicate spurious UEs.
|
||||
* Allow the h/w to stop working completely in case of a real UE.
|
||||
* Hence not setting the hw_error for UE detection.
|
||||
*/
|
||||
if (sliport_status & SLIPORT_STATUS_ERR_MASK) {
|
||||
adapter->hw_error = true;
|
||||
dev_err(&adapter->pdev->dev,
|
||||
"Error detected in the card\n");
|
||||
|