iio: pressure: bmp280: fix relative humidity unit

According to IIO ABI relative humidity reading should be
returned in milli percent.

This patch addresses that by applying proper scaling and
returning integer instead of fractional format type specifier.

Note that the fixes tag is before the driver was heavily refactored
to introduce spi support, so the patch won't apply that far back.

Signed-off-by: Tomasz Duszynski <tduszyns@gmail.com>
Fixes: 14beaa8f5a ("iio: pressure: bmp280: add humidity support")
Acked-by: Matt Ranostay <matt.ranostay@konsulko.com>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
This commit is contained in:
Tomasz Duszynski 2018-05-28 17:38:59 +02:00 committed by Jonathan Cameron
parent ce397d215c
commit 13399ff25f

View File

@ -415,10 +415,9 @@ static int bmp280_read_humid(struct bmp280_data *data, int *val, int *val2)
}
comp_humidity = bmp280_compensate_humidity(data, adc_humidity);
*val = comp_humidity;
*val2 = 1024;
*val = comp_humidity * 1000 / 1024;
return IIO_VAL_FRACTIONAL;
return IIO_VAL_INT;
}
static int bmp280_read_raw(struct iio_dev *indio_dev,