CHANGES
|
||
|
|
||
|
- 0.3 - Created based off of scanner & INSTALL from the original touchscreen
|
||
|
driver on freshmeat (http://freshmeat.net/projects/3mtouchscreendriver)
|
||
|
- Amended for linux-2.4.18, then 2.4.19
|
||
|
|
||
|
- 0.5 - Complete rewrite using Linux Input in 2.6.3
|
||
|
Unfortunately no calibration support at this time
|
||
|
|
||
|
- 1.4 - Multiple changes to support the EXII 5000UC and house cleaning
|
||
|
Changed reset from standard USB dev reset to vendor reset
|
||
|
Changed data sent to host from compensated to raw coordinates
|
||
|
Eliminated vendor/product module params
|
||
|
Performed multiple successfull tests with an EXII-5010UC
|
||
|
|
||
|
SUPPORTED HARDWARE:
|
||
|
|
||
|
All controllers have the Vendor: 0x0596 & Product: 0x0001
|
||
|
|
||
|
|
||
|
Controller Description Part Number
|
||
|
------------------------------------------------------
|
||
|
|
||
|
USB Capacitive - Pearl Case 14-205 (Discontinued)
|
||
|
USB Capacitive - Black Case 14-124 (Discontinued)
|
||
|
USB Capacitive - No Case 14-206 (Discontinued)
|
||
|
|
||
|
USB Capacitive - Pearl Case EXII-5010UC
|
||
|
USB Capacitive - Black Case EXII-5030UC
|
||
|
USB Capacitive - No Case EXII-5050UC
|
||
|
|
||
|
DRIVER NOTES:
|
||
|
|
||
|
Installation is simple, you only need to add Linux Input, Linux USB, and the
|
||
|
driver to the kernel. The driver can also be optionally built as a module.
|
||
|
|
||
|
This driver appears to be one of possible 2 Linux USB Input Touchscreen
|
||
|
drivers. Although 3M produces a binary only driver available for
|
||
|
download, I persist in updating this driver since I would like to use the
|
||
|
touchscreen for embedded apps using QTEmbedded, DirectFB, etc. So I feel the
|
||
|
logical choice is to use Linux Imput.
|
||
|
|
||
|
Currently there is no way to calibrate the device via this driver. Even if
|
||
|
the device could be calibrated, the driver pulls to raw coordinate data from
|
||
|
the controller. This means calibration must be performed within the
|
||
|
userspace.
|
||
|
|
||
|
The controller screen resolution is now 0 to 16384 for both X and Y reporting
|
||
|
the raw touch data. This is the same for the old and new capacitive USB
|
||
|
controllers.
|
||
|
|
||
|
Perhaps at some point an abstract function will be placed into evdev so
|
||
|
generic functions like calibrations, resets, and vendor information can be
|
||
|
requested from the userspace (And the drivers would handle the vendor specific
|
||
|
tasks).
|
||
|
|
||
|
ADDITIONAL INFORMATION/UPDATES/X CONFIGURATION EXAMPLE:
|
||
|
|
||
|
http://groomlakelabs.com/grandamp/code/microtouch/
|
||
|
|
||
|
TODO:
|
||
|
|
||
|
Implement a control urb again to handle requests to and from the device
|
||
|
such as calibration, etc once/if it becomes available.
|
||
|
|
||
|
DISCLAMER:
|
||
|
|
||
|
I am not a MicroTouch/3M employee, nor have I ever been. 3M does not support
|
||
|
this driver! If you want touch drivers only supported within X, please go to:
|
||
|
|
||
|
http://www.3m.com/3MTouchSystems/downloads/
|
||
|
|
||
|
THANKS:
|
||
|
|
||
|
A huge thank you to 3M Touch Systems for the EXII-5010UC controllers for
|
||
|
testing!
|