mirror of
https://github.com/torvalds/linux.git
synced 2024-11-17 01:22:07 +00:00
4231f9d166
This prevents use of this driver with ACPI via PRP0001 and is an example of an anti pattern I'm trying to remove from IIO. Hence drop from this driver. Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com> Reviewed-by: Andy Shevchenko <andy.shevchenko@gmail.com> Cc: David Barksdale <dbarksdale@uplogix.com> Link: https://lore.kernel.org/r/20200910173242.621168-38-jic23@kernel.org
167 lines
4.4 KiB
C
167 lines
4.4 KiB
C
// SPDX-License-Identifier: GPL-2.0-only
|
|
/*
|
|
* si7020.c - Silicon Labs Si7013/20/21 Relative Humidity and Temp Sensors
|
|
* Copyright (c) 2013,2014 Uplogix, Inc.
|
|
* David Barksdale <dbarksdale@uplogix.com>
|
|
*/
|
|
|
|
/*
|
|
* The Silicon Labs Si7013/20/21 Relative Humidity and Temperature Sensors
|
|
* are i2c devices which have an identical programming interface for
|
|
* measuring relative humidity and temperature. The Si7013 has an additional
|
|
* temperature input which this driver does not support.
|
|
*
|
|
* Data Sheets:
|
|
* Si7013: http://www.silabs.com/Support%20Documents/TechnicalDocs/Si7013.pdf
|
|
* Si7020: http://www.silabs.com/Support%20Documents/TechnicalDocs/Si7020.pdf
|
|
* Si7021: http://www.silabs.com/Support%20Documents/TechnicalDocs/Si7021.pdf
|
|
*/
|
|
|
|
#include <linux/delay.h>
|
|
#include <linux/i2c.h>
|
|
#include <linux/module.h>
|
|
#include <linux/mod_devicetable.h>
|
|
#include <linux/slab.h>
|
|
#include <linux/sysfs.h>
|
|
|
|
#include <linux/iio/iio.h>
|
|
#include <linux/iio/sysfs.h>
|
|
|
|
/* Measure Relative Humidity, Hold Master Mode */
|
|
#define SI7020CMD_RH_HOLD 0xE5
|
|
/* Measure Temperature, Hold Master Mode */
|
|
#define SI7020CMD_TEMP_HOLD 0xE3
|
|
/* Software Reset */
|
|
#define SI7020CMD_RESET 0xFE
|
|
|
|
static int si7020_read_raw(struct iio_dev *indio_dev,
|
|
struct iio_chan_spec const *chan, int *val,
|
|
int *val2, long mask)
|
|
{
|
|
struct i2c_client **client = iio_priv(indio_dev);
|
|
int ret;
|
|
|
|
switch (mask) {
|
|
case IIO_CHAN_INFO_RAW:
|
|
ret = i2c_smbus_read_word_swapped(*client,
|
|
chan->type == IIO_TEMP ?
|
|
SI7020CMD_TEMP_HOLD :
|
|
SI7020CMD_RH_HOLD);
|
|
if (ret < 0)
|
|
return ret;
|
|
*val = ret >> 2;
|
|
/*
|
|
* Humidity values can slightly exceed the 0-100%RH
|
|
* range and should be corrected by software
|
|
*/
|
|
if (chan->type == IIO_HUMIDITYRELATIVE)
|
|
*val = clamp_val(*val, 786, 13893);
|
|
return IIO_VAL_INT;
|
|
case IIO_CHAN_INFO_SCALE:
|
|
if (chan->type == IIO_TEMP)
|
|
*val = 175720; /* = 175.72 * 1000 */
|
|
else
|
|
*val = 125 * 1000;
|
|
*val2 = 65536 >> 2;
|
|
return IIO_VAL_FRACTIONAL;
|
|
case IIO_CHAN_INFO_OFFSET:
|
|
/*
|
|
* Since iio_convert_raw_to_processed_unlocked assumes offset
|
|
* is an integer we have to round these values and lose
|
|
* accuracy.
|
|
* Relative humidity will be 0.0032959% too high and
|
|
* temperature will be 0.00277344 degrees too high.
|
|
* This is no big deal because it's within the accuracy of the
|
|
* sensor.
|
|
*/
|
|
if (chan->type == IIO_TEMP)
|
|
*val = -4368; /* = -46.85 * (65536 >> 2) / 175.72 */
|
|
else
|
|
*val = -786; /* = -6 * (65536 >> 2) / 125 */
|
|
return IIO_VAL_INT;
|
|
default:
|
|
break;
|
|
}
|
|
|
|
return -EINVAL;
|
|
}
|
|
|
|
static const struct iio_chan_spec si7020_channels[] = {
|
|
{
|
|
.type = IIO_HUMIDITYRELATIVE,
|
|
.info_mask_separate = BIT(IIO_CHAN_INFO_RAW) |
|
|
BIT(IIO_CHAN_INFO_SCALE) | BIT(IIO_CHAN_INFO_OFFSET),
|
|
},
|
|
{
|
|
.type = IIO_TEMP,
|
|
.info_mask_separate = BIT(IIO_CHAN_INFO_RAW) |
|
|
BIT(IIO_CHAN_INFO_SCALE) | BIT(IIO_CHAN_INFO_OFFSET),
|
|
}
|
|
};
|
|
|
|
static const struct iio_info si7020_info = {
|
|
.read_raw = si7020_read_raw,
|
|
};
|
|
|
|
static int si7020_probe(struct i2c_client *client,
|
|
const struct i2c_device_id *id)
|
|
{
|
|
struct iio_dev *indio_dev;
|
|
struct i2c_client **data;
|
|
int ret;
|
|
|
|
if (!i2c_check_functionality(client->adapter,
|
|
I2C_FUNC_SMBUS_WRITE_BYTE |
|
|
I2C_FUNC_SMBUS_READ_WORD_DATA))
|
|
return -EOPNOTSUPP;
|
|
|
|
/* Reset device, loads default settings. */
|
|
ret = i2c_smbus_write_byte(client, SI7020CMD_RESET);
|
|
if (ret < 0)
|
|
return ret;
|
|
/* Wait the maximum power-up time after software reset. */
|
|
msleep(15);
|
|
|
|
indio_dev = devm_iio_device_alloc(&client->dev, sizeof(*data));
|
|
if (!indio_dev)
|
|
return -ENOMEM;
|
|
|
|
data = iio_priv(indio_dev);
|
|
*data = client;
|
|
|
|
indio_dev->name = dev_name(&client->dev);
|
|
indio_dev->modes = INDIO_DIRECT_MODE;
|
|
indio_dev->info = &si7020_info;
|
|
indio_dev->channels = si7020_channels;
|
|
indio_dev->num_channels = ARRAY_SIZE(si7020_channels);
|
|
|
|
return devm_iio_device_register(&client->dev, indio_dev);
|
|
}
|
|
|
|
static const struct i2c_device_id si7020_id[] = {
|
|
{ "si7020", 0 },
|
|
{ "th06", 0 },
|
|
{ }
|
|
};
|
|
MODULE_DEVICE_TABLE(i2c, si7020_id);
|
|
|
|
static const struct of_device_id si7020_dt_ids[] = {
|
|
{ .compatible = "silabs,si7020" },
|
|
{ }
|
|
};
|
|
MODULE_DEVICE_TABLE(of, si7020_dt_ids);
|
|
|
|
static struct i2c_driver si7020_driver = {
|
|
.driver = {
|
|
.name = "si7020",
|
|
.of_match_table = si7020_dt_ids,
|
|
},
|
|
.probe = si7020_probe,
|
|
.id_table = si7020_id,
|
|
};
|
|
|
|
module_i2c_driver(si7020_driver);
|
|
MODULE_DESCRIPTION("Silicon Labs Si7013/20/21 Relative Humidity and Temperature Sensors");
|
|
MODULE_AUTHOR("David Barksdale <dbarksdale@uplogix.com>");
|
|