mirror of
https://github.com/torvalds/linux.git
synced 2024-11-19 18:41:48 +00:00
10ed7e9847
Olof Johansson pointed out that usually the company name is picked as namespace prefix to specific properties. So expect "energymicro,location" but fall back to the previously introduced name "efm32,location". Signed-off-by: Uwe Kleine-König <u.kleine-koenig@pengutronix.de> Signed-off-by: Mark Brown <broonie@linaro.org>
42 lines
1.2 KiB
Plaintext
42 lines
1.2 KiB
Plaintext
* Energy Micro EFM32 SPI
|
|
|
|
Required properties:
|
|
- #address-cells: see spi-bus.txt
|
|
- #size-cells: see spi-bus.txt
|
|
- compatible: should be "energymicro,efm32-spi"
|
|
- reg: Offset and length of the register set for the controller
|
|
- interrupts: pair specifying rx and tx irq
|
|
- clocks: phandle to the spi clock
|
|
- cs-gpios: see spi-bus.txt
|
|
|
|
Recommended properties :
|
|
- energymicro,location: Value to write to the ROUTE register's LOCATION
|
|
bitfield to configure the pinmux for the device, see
|
|
datasheet for values.
|
|
If this property is not provided, keeping what is
|
|
already configured in the hardware, so its either the
|
|
reset default 0 or whatever the bootloader did.
|
|
|
|
Example:
|
|
|
|
spi1: spi@0x4000c400 { /* USART1 */
|
|
#address-cells = <1>;
|
|
#size-cells = <0>;
|
|
compatible = "energymicro,efm32-spi";
|
|
reg = <0x4000c400 0x400>;
|
|
interrupts = <15 16>;
|
|
clocks = <&cmu 20>;
|
|
cs-gpios = <&gpio 51 1>; // D3
|
|
energymicro,location = <1>;
|
|
status = "ok";
|
|
|
|
ks8851@0 {
|
|
compatible = "ks8851";
|
|
spi-max-frequency = <6000000>;
|
|
reg = <0>;
|
|
interrupt-parent = <&boardfpga>;
|
|
interrupts = <4>;
|
|
status = "ok";
|
|
};
|
|
};
|