40257b953f
Temperature alarms are detected by checking the alarm bit and comparing temperature limits against the current temperature. For low limits, this comparison needs to be reversed (temp < limit instead of temp > limit). This was not taken into account, resulting in wrong alarms if a temperature fell below a low limit. Fix by adding a low limit flag in the limit data structure. When creating the sensor entry, the order of registers to compare is now reversed for low limits. Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com> Acked-by: Jean Delvare <khali@linux-fr.org> Cc: stable@kernel.org # 3.0+ |
||
---|---|---|
.. | ||