linux/Documentation/admin-guide/edid.rst
Maxime Ripard 89ac522d45
drm/edid/firmware: Remove built-in EDIDs
The EDID firmware loading mechanism introduced a few built-in EDIDs that
could be forced on any connector, bypassing the EDIDs it exposes.

While convenient, this limited set of EDIDs doesn't take into account
the connector type, and we can end up with an EDID that is completely
invalid for a given connector.

For example, the edid/800x600.bin file matches the following EDID:

  edid-decode (hex):

  00 ff ff ff ff ff ff 00 31 d8 00 00 00 00 00 00
  05 16 01 03 6d 1b 14 78 ea 5e c0 a4 59 4a 98 25
  20 50 54 01 00 00 45 40 01 01 01 01 01 01 01 01
  01 01 01 01 01 01 a0 0f 20 00 31 58 1c 20 28 80
  14 00 15 d0 10 00 00 1e 00 00 00 ff 00 4c 69 6e
  75 78 20 23 30 0a 20 20 20 20 00 00 00 fd 00 3b
  3d 24 26 05 00 0a 20 20 20 20 20 20 00 00 00 fc
  00 4c 69 6e 75 78 20 53 56 47 41 0a 20 20 00 c2

  ----------------

  Block 0, Base EDID:
    EDID Structure Version & Revision: 1.3
    Vendor & Product Identification:
      Manufacturer: LNX
      Model: 0
      Made in: week 5 of 2012
    Basic Display Parameters & Features:
      Analog display
      Signal Level Standard: 0.700 : 0.000 : 0.700 V p-p
      Blank level equals black level
      Sync: Separate Composite Serration
      Maximum image size: 27 cm x 20 cm
      Gamma: 2.20
      DPMS levels: Standby Suspend Off
      RGB color display
      First detailed timing is the preferred timing
    Color Characteristics:
      Red  : 0.6416, 0.3486
      Green: 0.2919, 0.5957
      Blue : 0.1474, 0.1250
      White: 0.3125, 0.3281
    Established Timings I & II:
      DMT 0x09:   800x600    60.316541 Hz   4:3     37.879 kHz     40.000000 MHz
    Standard Timings:
      DMT 0x09:   800x600    60.316541 Hz   4:3     37.879 kHz     40.000000 MHz
    Detailed Timing Descriptors:
      DTD 1:   800x600    60.316541 Hz   4:3     37.879 kHz     40.000000 MHz (277 mm x 208 mm)
                   Hfront   40 Hsync 128 Hback   88 Hpol P
                   Vfront    1 Vsync   4 Vback   23 Vpol P
      Display Product Serial Number: 'Linux #0'
      Display Range Limits:
        Monitor ranges (GTF): 59-61 Hz V, 36-38 kHz H, max dotclock 50 MHz
      Display Product Name: 'Linux SVGA'
  Checksum: 0xc2

So, an analog monitor EDID. However, if the connector was an HDMI
monitor for example, it breaks the HDMI specification that requires,
among other things, a digital display, the VIC 1 mode and an HDMI Forum
Vendor Specific Data Block in an CTA-861 extension.

We thus end up with a completely invalid EDID, which thus might confuse
HDMI-related code that could parse it.

After some discussions on IRC, we identified mainly two ways to fix
this:

  - We can either create more EDIDs for each connector type to provide
    a built-in EDID that matches the resolution passed in the name, and
    still be a sensible EDID for that connector type;

  - Or we can just prevent the EDID to be exposed to userspace if it's
    built-in.

Or possibly both.

However, the conclusion was that maybe we just don't need the built-in
EDIDs at all and we should just get rid of them. So here we are.

Acked-by: Daniel Vetter <daniel.vetter@ffwll.ch>
Acked-by: Jani Nikula <jani.nikula@intel.com>
Acked-by: Pekka Paalanen <pekka.paalanen@collabora.com>
Acked-by: Thomas Zimmermann <tzimmermann@suse.de>
Signed-off-by: Maxime Ripard <mripard@kernel.org>
Link: https://patchwork.freedesktop.org/patch/msgid/20240221092636.691701-1-mripard@kernel.org
2024-02-26 14:05:18 +01:00

28 lines
1.1 KiB
ReStructuredText

.. SPDX-License-Identifier: GPL-2.0
====
EDID
====
In the good old days when graphics parameters were configured explicitly
in a file called xorg.conf, even broken hardware could be managed.
Today, with the advent of Kernel Mode Setting, a graphics board is
either correctly working because all components follow the standards -
or the computer is unusable, because the screen remains dark after
booting or it displays the wrong area. Cases when this happens are:
- The graphics board does not recognize the monitor.
- The graphics board is unable to detect any EDID data.
- The graphics board incorrectly forwards EDID data to the driver.
- The monitor sends no or bogus EDID data.
- A KVM sends its own EDID data instead of querying the connected monitor.
Adding the kernel parameter "nomodeset" helps in most cases, but causes
restrictions later on.
As a remedy for such situations, the kernel configuration item
CONFIG_DRM_LOAD_EDID_FIRMWARE was introduced. It allows to provide an
individually prepared or corrected EDID data set in the /lib/firmware
directory from where it is loaded via the firmware interface.