Some of the were relying into smp.h being dragged in by another header
which of course is fragile. <asm/cpu-info.h> uses smp_processor_id()
only in macros and including smp.h there leads to an include loop, so
don't change cpu-info.h.
Signed-off-by: Ralf Baechle <ralf@linux-mips.org>
Impact: cleanup
It's unused, since about 1995. So remove all initialization of it in
preparation for actually removing the field.
Signed-off-by: Rusty Russell <rusty@rustcorp.com.au>
Acked-by: Thomas Gleixner <tglx@linutronix.de>
Impact: change calling convention of existing clock_event APIs
struct clock_event_timer's cpumask field gets changed to take pointer,
as does the ->broadcast function.
Another single-patch change. For safety, we BUG_ON() in
clockevents_register_device() if it's not set.
Signed-off-by: Rusty Russell <rusty@rustcorp.com.au>
Cc: Ingo Molnar <mingo@elte.hu>
Impact: change existing irq_chip API
Not much point with gentle transition here: the struct irq_chip's
setaffinity method signature needs to change.
Fortunately, not widely used code, but hits a few architectures.
Note: In irq_select_affinity() I save a temporary in by mangling
irq_desc[irq].affinity directly. Ingo, does this break anything?
(Folded in fix from KOSAKI Motohiro)
Signed-off-by: Rusty Russell <rusty@rustcorp.com.au>
Signed-off-by: Mike Travis <travis@sgi.com>
Reviewed-by: Grant Grundler <grundler@parisc-linux.org>
Acked-by: Ingo Molnar <mingo@redhat.com>
Cc: ralf@linux-mips.org
Cc: grundler@parisc-linux.org
Cc: jeremy@xensource.com
Cc: KOSAKI Motohiro <kosaki.motohiro@jp.fujitsu.com>
We have no guarantee by the generic time code that the timer is stopped
when the ->next_event method is called. Modifying the Timer Initial Count
register while the timer is enabled has UNPREDICTABLE effect according to
the BCM1250/BCM1125/BCM1125H User Manual. So stop the timer before
reprogramming.
This is a paranoia fix; no ill effects have been observed previously.
Signed-off-by: Ralf Baechle <ralf@linux-mips.org>
For the old minimum of a single tick a value of zero would be programmed
into the init value register which in the BCM1250/BCM1125/BCM1125H User
Manual in the Timer Special Cases section is documented to have
UNPREDICTABLE effect.
Observable sympthoms of this bug were hangs of several seconds on the
console during bootup and later if both dyntick and highres timer options
were activated.
In theory contiguous mode of the timers is also affected but in an act of
hopeless lack of realism I'll assume nobody will ever configure a KERNEL
for HZ > 500kHz but if so I leave that to evolution to sort out.
Signed-off-by: Ralf Baechle <ralf@linux-mips.org>