Fix voltage conversion routines. Based on an earlier patch from
Paulius Zaleckas.
According to the datasheet voltage is scaled with resistors and
value 192 is nominal voltage. 0 is 0V.
Signed-off-by: Jean Delvare <khali@linux-fr.org>
Cc: Paulius Zaleckas <paulius.zaleckas@teltonika.lt>
Cc: Darrick J. Wong <djwong@us.ibm.com>
All the *_MAX_ADDR defines are never used, so remove them. The number
of registers of each type is already expressed by the *_COUNT defines.
Signed-off-by: Jean Delvare <khali@linux-fr.org>
Acked-by: Darrick J. Wong <djwong@us.ibm.com>
Signed-off-by: Mark M. Hoffman <mhoffman@lightlink.com>
The new-style adt7473 driver implements the optional detect() callback
to cover the use cases of the legacy driver.
Signed-off-by: Jean Delvare <khali@linux-fr.org>
Cc: Darrick J. Wong <djwong@us.ibm.com>
data->max_duty_at_overheat is not updated in adt7473_update_device,
so it might be used before it is initialized (if the user reads from
sysfs file max_duty_at_crit before writing to it.)
Signed-off-by: Jean Delvare <khali@linux-fr.org>
Acked-by: Darrick J. Wong <djwong@us.ibm.com>
Signed-off-by: Mark M. Hoffman <mhoffman@lightlink.com>
This driver reports voltage, temperature and fan sensor readings
on an ADT7473 chip.
Signed-off-by: Darrick J. Wong <djwong@us.ibm.com>
Signed-off-by: Mark M. Hoffman <mhoffman@lightlink.com>