The .remove() callback for a platform driver returns an int which makes
many driver authors wrongly assume it's possible to do error handling by
returning an error code. However the value returned is ignored (apart
from emitting a warning) and this typically results in resource leaks.
To improve here there is a quest to make the remove callback return
void. In the first step of this quest all drivers are converted to
.remove_new(), which already returns void. Eventually after all drivers
are converted, .remove_new() will be renamed to .remove().
Trivially convert this driver from always returning zero in the remove
callback to the void returning variant.
Signed-off-by: Uwe Kleine-König <u.kleine-koenig@pengutronix.de>
Link: https://lore.kernel.org/r/20240410124707.194228-2-u.kleine-koenig@pengutronix.de
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
Fix the following fallthrough warnings (powernv_defconfig and powerpc64):
drivers/char/powernv-op-panel.c:78:2: warning: unannotated fall-through between switch labels [-Wimplicit-fallthrough]
Reported-by: Nathan Chancellor <nathan@kernel.org>
Signed-off-by: Gustavo A. R. Silva <gustavoars@kernel.org>
Add SPDX license identifiers to all files which:
- Have no license information of any form
- Have MODULE_LICENCE("GPL*") inside which was used in the initial
scan/conversion to ignore the file
These files fall under the project license, GPL v2 only. The resulting SPDX
license identifier is:
GPL-2.0-only
Signed-off-by: Thomas Gleixner <tglx@linutronix.de>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
Implement new character device driver to allow access from user space
to the operator panel display present on IBM Power Systems machines
with FSPs.
This will allow status information to be presented on the display which
is visible to a user.
The driver implements a character buffer which a user can read/write
by accessing the device (/dev/op_panel). This buffer is then displayed on
the operator panel display. Any attempt to write past the last character
position will have no effect and attempts to write more characters than
the size of the display will be truncated. The device may only be accessed
by a single process at a time.
Signed-off-by: Suraj Jitindar Singh <sjitindarsingh@gmail.com>
Reviewed-by: Andrew Donnellan <andrew.donnellan@au1.ibm.com>
Signed-off-by: Michael Ellerman <mpe@ellerman.id.au>