Found during code inspection, that the following functions are not
being used outside of the file where they are defined. Make them static.
int cxlflash_send_cmd(struct afu *, struct afu_cmd *);
void cxlflash_wait_resp(struct afu *, struct afu_cmd *);
int cxlflash_afu_reset(struct cxlflash_cfg *);
struct afu_cmd *cxlflash_cmd_checkout(struct afu *);
void cxlflash_cmd_checkin(struct afu_cmd *);
void init_pcr(struct cxlflash_cfg *);
int init_global(struct cxlflash_cfg *);
Signed-off-by: Matthew R. Ochs <mrochs@linux.vnet.ibm.com>
Signed-off-by: Manoj N. Kumar <manoj@linux.vnet.ibm.com>
Reviewed-by: Brian King <brking@linux.vnet.ibm.com>
Reviewed-by: Tomas Henzl <thenzl@redhat.com>
Signed-off-by: James Bottomley <JBottomley@Odin.com>
Limbo is not an accurate representation of this state and is
also not consistent with the terminology that other drivers
use to represent this concept. Rename the state and and its
associated waitq to 'reset'.
Signed-off-by: Matthew R. Ochs <mrochs@linux.vnet.ibm.com>
Signed-off-by: Manoj N. Kumar <manoj@linux.vnet.ibm.com>
Reviewed-by: Brian King <brking@linux.vnet.ibm.com>
Reviewed-by: Daniel Axtens <dja@axtens.net>
Reviewed-by: Tomas Henzl <thenzl@redhat.com>
Signed-off-by: James Bottomley <JBottomley@Odin.com>
During an EEH freeze event, certain CXL services should not be
called until after the hardware reset has taken place. Doing so
can result in unnecessary failures and possibly cause other ill
effects by triggering hardware accesses. This translates to a
requirement to quiesce all threads that may potentially use CXL
runtime service during this window. In particular, multiple ioctls
make use of the CXL services when acting on contexts on behalf of
the user. Thus, it is essential to 'drain' running ioctls _before_
proceeding with handling the EEH freeze event.
Create the ability to drain ioctls by wrapping the ioctl handler
call in a read semaphore and then implementing a small routine that
obtains the write semaphore, effectively creating a wait point for
all currently executing ioctls.
Signed-off-by: Matthew R. Ochs <mrochs@linux.vnet.ibm.com>
Signed-off-by: Manoj N. Kumar <manoj@linux.vnet.ibm.com>
Reviewed-by: Brian King <brking@linux.vnet.ibm.com>
Reviewed-by: Daniel Axtens <dja@axtens.net>
Reviewed-by: Tomas Henzl <thenzl@redhat.com>
Signed-off-by: James Bottomley <JBottomley@Odin.com>
The context encode mask covers more than 32-bits, making it
a long integer. This should be noted by appending the ULL
width suffix to the mask.
Signed-off-by: Matthew R. Ochs <mrochs@linux.vnet.ibm.com>
Signed-off-by: Manoj N. Kumar <manoj@linux.vnet.ibm.com>
Reviewed-by: Brian King <brking@linux.vnet.ibm.com>
Reviewed-by: Daniel Axtens <dja@axtens.net>
Reviewed-by: Tomas Henzl <thenzl@redhat.com>
Signed-off-by: James Bottomley <JBottomley@Odin.com>
Using sizeof(bool) is considered poor form for various reasons and
sparse warns us of that. Correct by changing type from bool to u8.
Signed-off-by: Matthew R. Ochs <mrochs@linux.vnet.ibm.com>
Signed-off-by: Manoj N. Kumar <manoj@linux.vnet.ibm.com>
Reviewed-by: Brian King <brking@linux.vnet.ibm.com>
Reviewed-by: Daniel Axtens <dja@axtens.net>
Reviewed-by: Tomas Henzl <thenzl@redhat.com>
Signed-off-by: James Bottomley <JBottomley@Odin.com>
If the same virtual LUN is accessed over multiple cards, only accesses
made over the first card will be valid. Accesses made over the second
card will go to the wrong LUN causing data corruption.
This is because the global LUN's mode word was being used to determine
whether the LUN table for that card needs to be programmed. The mode
word would be setup by the first card, causing the LUN table for the
second card to not be programmed.
By unconditionally initializing the LUN table (not depending on the
mode word), the problem is avoided.
Signed-off-by: Matthew R. Ochs <mrochs@linux.vnet.ibm.com>
Signed-off-by: Manoj N. Kumar <manoj@linux.vnet.ibm.com>
Reviewed-by: Brian King <brking@linux.vnet.ibm.com>
Reviewed-by: Tomas Henzl <thenzl@redhat.com>
Signed-off-by: James Bottomley <JBottomley@Odin.com>
When a LUN is removed, the sdev that is associated with the LUN
remains intact until its reference count drops to 0. In order
to prevent an sdev from being removed while a context is still
associated with it, obtain an additional reference per-context
for each LUN attached to the context.
This resolves a potential Oops in the release handler when a
dealing with a LUN that has already been removed.
Signed-off-by: Matthew R. Ochs <mrochs@linux.vnet.ibm.com>
Signed-off-by: Manoj N. Kumar <manoj@linux.vnet.ibm.com>
Reviewed-by: Brian King <brking@linux.vnet.ibm.com>
Reviewed-by: Tomas Henzl <thenzl@redhat.com>
Signed-off-by: James Bottomley <JBottomley@Odin.com>
The timeout value for read capacity is too small. Certain devices
may take longer to respond and thus the command may prematurely
timeout. Additionally the literal used for the timeout is stale.
Update the timeout to 30 seconds (matches the value used in sd.c)
and rework the timeout literal to a more appropriate description.
Signed-off-by: Matthew R. Ochs <mrochs@linux.vnet.ibm.com>
Signed-off-by: Manoj N. Kumar <manoj@linux.vnet.ibm.com>
Reviewed-by: Brian King <brking@linux.vnet.ibm.com>
Reviewed-by: Tomas Henzl <thenzl@redhat.com>
Signed-off-by: James Bottomley <JBottomley@Odin.com>
Magic numbers are not meaningful and can create confusion. As a
remedy, replace them with descriptive literals.
Replace 512 with literal MAX_SECTOR_UNIT.
Replace 5 with literal CMD_RETRIES.
Signed-off-by: Matthew R. Ochs <mrochs@linux.vnet.ibm.com>
Signed-off-by: Manoj N. Kumar <manoj@linux.vnet.ibm.com>
Reviewed-by: Brian King <brking@linux.vnet.ibm.com>
Reviewed-by: Andrew Donnellan <andrew.donnellan@au1.ibm.com>
Reviewed-by: Tomas Henzl <thenzl@redhat.com>
Signed-off-by: James Bottomley <JBottomley@Odin.com>
If two concurrent MANAGE_LUN ioctls are issued with the same
WWID parameter, it would result in an incorrect value of port_sel.
This is because port_sel is modified without any locks being
held. If the first caller stalls after the return from
find_and_create_lun(), the value of port_sel will be set
incorrectly to indicate a single port, though in this case
it should have been set to both ports.
To fix, use the global mutex to serialize the lookup of the
WWID and the subsequent modification of port_sel.
Signed-off-by: Matthew R. Ochs <mrochs@linux.vnet.ibm.com>
Signed-off-by: Manoj N. Kumar <manoj@linux.vnet.ibm.com>
Reviewed-by: Brian King <brking@linux.vnet.ibm.com>
Reviewed-by: Tomas Henzl <thenzl@redhat.com>
Signed-off-by: James Bottomley <JBottomley@Odin.com>
The queuecommand routine has a local dev pointer used for the
dev_* prints. The two prints that currently exist are tucked
under a debug define and thus can be left out. Use the actual
location instead of a local to avoid this warning.
This patch is intended to be applied after the "CXL Flash Error
Recovery and Superpipe" series.
Signed-off-by: Matthew R. Ochs <mrochs@linux.vnet.ibm.com>
Signed-off-by: Manoj N. Kumar <manoj@linux.vnet.ibm.com>
Reported-by: kbuild test robot <fengguang.wu@intel.com>
Signed-off-by: James Bottomley <JBottomley@Odin.com>
"port_sel" is a u64 so the shifting should also be a 64 bit shift.
Fixes: c21e0bbfc4 ('cxlflash: Base support for IBM CXL Flash Adapter')
Signed-off-by: Dan Carpenter <dan.carpenter@oracle.com>
Reviewed-by: Johannes Thumshirn <jthumshirn@suse.de>
Acked-by: Matthew R. Ochs <mrochs@linux.vnet.ibm.com>
Signed-off-by: James Bottomley <JBottomley@Odin.com>
The > should be >= or we read one element past the end of the array.
Fixes: c21e0bbfc4 ('cxlflash: Base support for IBM CXL Flash Adapter')
Signed-off-by: Dan Carpenter <dan.carpenter@oracle.com>
Acked-by: Matthew R. Ochs <mrochs@linux.vnet.ibm.com>
Signed-off-by: James Bottomley <JBottomley@Odin.com>
Add support for physical LUN segmentation (virtual LUNs) to device
driver supporting the IBM CXL Flash adapter. This patch allows user
space applications to virtually segment a physical LUN into N virtual
LUNs, taking advantage of the translation features provided by this
adapter.
Signed-off-by: Matthew R. Ochs <mrochs@linux.vnet.ibm.com>
Signed-off-by: Manoj N. Kumar <manoj@linux.vnet.ibm.com>
Reviewed-by: Michael Neuling <mikey@neuling.org>
Reviewed-by: Wen Xiong <wenxiong@linux.vnet.ibm.com>
Signed-off-by: James Bottomley <JBottomley@Odin.com>
Add superpipe supporting infrastructure to device driver for the IBM CXL
Flash adapter. This patch allows userspace applications to take advantage
of the accelerated I/O features that this adapter provides and bypass the
traditional filesystem stack.
Signed-off-by: Matthew R. Ochs <mrochs@linux.vnet.ibm.com>
Signed-off-by: Manoj N. Kumar <manoj@linux.vnet.ibm.com>
Reviewed-by: Michael Neuling <mikey@neuling.org>
Reviewed-by: Wen Xiong <wenxiong@linux.vnet.ibm.com>
Reviewed-by: Brian King <brking@linux.vnet.ibm.com>
Signed-off-by: James Bottomley <JBottomley@Odin.com>
Introduce support for enhanced I/O error handling.
A device state is added to track 3 possible states of the device:
Normal - the device is operating normally and is fully operational
Limbo - the device is in a reset/recovery scenario and its operational
status is paused
Failed/terminating - the device has either failed to be reset/recovered
or is being terminated (removed); it is no longer
operational
All operations are allowed when the device is operating normally. When the
device transitions to limbo state, I/O must be paused. To help accomplish
this, a wait queue is introduced where existing and new threads can wait
until the device is no longer in limbo. When coming out of limbo, threads
need to check the state and error out gracefully when encountering the
failed state. When the device transitions to the failed/terminating state,
normal operations are no longer allowed. Only specially designated
operations related to graceful cleanup are permitted.
Signed-off-by: Matthew R. Ochs <mrochs@linux.vnet.ibm.com>
Signed-off-by: Manoj N. Kumar <manoj@linux.vnet.ibm.com>
Reviewed-by: Daniel Axtens <dja@axtens.net>
Reviewed-by: Michael Neuling <mikey@neuling.org>
Reviewed-by: Wen Xiong <wenxiong@linux.vnet.ibm.com>
Reviewed-by: Brian King <brking@linux.vnet.ibm.com>
Signed-off-by: James Bottomley <JBottomley@Odin.com>
SCSI device driver to support filesystem access on the IBM CXL Flash adapter.
Supported-by: Stephen Bates <stephen.bates@pmcs.com>
Reviewed-by: Michael Neuling <mikey@neuling.org>
Signed-off-by: Matthew R. Ochs <mrochs@linux.vnet.ibm.com>
Signed-off-by: Manoj N. Kumar <manoj@linux.vnet.ibm.com>
Reviewed-by: Brian King <brking@linux.vnet.ibm.com>
Signed-off-by: James Bottomley <JBottomley@Odin.com>