mirror of
https://github.com/torvalds/linux.git
synced 2024-11-17 01:22:07 +00:00
drm/i915: Do a dummy DPCD read before the actual read
Sometimes we seem to get utter garbage from DPCD reads. The resulting buffer is filled with the same byte, and the operation completed without errors. My HP ZR24w monitor seems particularly susceptible to this problem once it's gone into a sleep mode. The issue seems to happen only for the first AUX message that wakes the sink up. But as the first AUX read we often do is the DPCD receiver cap it does wreak a bit of havoc with subsequent link training etc. when the receiver cap bw/lane/etc. information is garbage. A sufficient workaround seems to be to perform a single byte dummy read before reading the actual data. I suppose that just wakes up the sink sufficiently and we can just throw away the returned data in case it's crap. DP_DPCD_REV seems like a sufficiently safe location to read here. Signed-off-by: Ville Syrjälä <ville.syrjala@linux.intel.com> Reviewed-by: Todd Previte <tprevite@gmail.com> Cc: stable@vger.kernel.org Signed-off-by: Jani Nikula <jani.nikula@intel.com>
This commit is contained in:
parent
cac7f24298
commit
f6a1906674
@ -2806,6 +2806,13 @@ intel_dp_dpcd_read_wake(struct drm_dp_aux *aux, unsigned int offset,
|
||||
ssize_t ret;
|
||||
int i;
|
||||
|
||||
/*
|
||||
* Sometime we just get the same incorrect byte repeated
|
||||
* over the entire buffer. Doing just one throw away read
|
||||
* initially seems to "solve" it.
|
||||
*/
|
||||
drm_dp_dpcd_read(aux, DP_DPCD_REV, buffer, 1);
|
||||
|
||||
for (i = 0; i < 3; i++) {
|
||||
ret = drm_dp_dpcd_read(aux, offset, buffer, size);
|
||||
if (ret == size)
|
||||
|
Loading…