clk: tegra30: Add hda clock default rates to clock driver

Current implementation defaults the hda clocks to clk_m. This causes hda
to run too slow to operate correctly. Fix this by defaulting to pll_p and
setting the frequency to the correct rate.

This matches upstream t124 and downstream t30.

Acked-by: Jon Hunter <jonathanh@nvidia.com>
Tested-by: Ion Agorria <ion@agorria.com>
Acked-by: Sameer Pujar <spujar@nvidia.com>
Acked-by: Thierry Reding <treding@nvidia.com>
Signed-off-by: Peter Geis <pgwipeout@gmail.com>
Link: https://lore.kernel.org/r/20210108135913.2421585-2-pgwipeout@gmail.com
Signed-off-by: Takashi Iwai <tiwai@suse.de>
This commit is contained in:
Peter Geis 2021-01-08 13:59:12 +00:00 committed by Takashi Iwai
parent 3e096a2112
commit f4eccc7fea

View File

@ -1256,6 +1256,8 @@ static struct tegra_clk_init_table init_table[] __initdata = {
{ TEGRA30_CLK_I2S3_SYNC, TEGRA30_CLK_CLK_MAX, 24000000, 0 },
{ TEGRA30_CLK_I2S4_SYNC, TEGRA30_CLK_CLK_MAX, 24000000, 0 },
{ TEGRA30_CLK_VIMCLK_SYNC, TEGRA30_CLK_CLK_MAX, 24000000, 0 },
{ TEGRA30_CLK_HDA, TEGRA30_CLK_PLL_P, 102000000, 0 },
{ TEGRA30_CLK_HDA2CODEC_2X, TEGRA30_CLK_PLL_P, 48000000, 0 },
/* must be the last entry */
{ TEGRA30_CLK_CLK_MAX, TEGRA30_CLK_CLK_MAX, 0, 0 },
};