power: supply: bq25890: Always take HiZ mode into account for ADC rate

The code to check if F_CONV_RATE has been set, or if a manual ADC
conversion needs to be triggered, as well as the code to set
the initial F_CONV_RATE value at probe both where not taking
HiZ mode into account. Add checks for this.

Reviewed-by: Marek Vasut <marex@denx.de>
Signed-off-by: Hans de Goede <hdegoede@redhat.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
This commit is contained in:
Hans de Goede 2022-11-28 10:28:53 +01:00 committed by Sebastian Reichel
parent 4413f9e913
commit dee0df8496

View File

@ -467,7 +467,7 @@ static void bq25890_update_state(struct bq25890_device *bq,
/* update state in case we lost an interrupt */
__bq25890_handle_irq(bq);
*state = bq->state;
do_adc_conv = !state->online && bq25890_is_adc_property(psp);
do_adc_conv = (!state->online || state->hiz) && bq25890_is_adc_property(psp);
if (do_adc_conv)
bq25890_field_write(bq, F_CONV_START, 1);
mutex_unlock(&bq->lock);
@ -956,7 +956,7 @@ static int bq25890_hw_init(struct bq25890_device *bq)
}
/* Configure ADC for continuous conversions when charging */
ret = bq25890_field_write(bq, F_CONV_RATE, !!bq->state.online);
ret = bq25890_field_write(bq, F_CONV_RATE, bq->state.online && !bq->state.hiz);
if (ret < 0) {
dev_dbg(bq->dev, "Config ADC failed %d\n", ret);
return ret;