mirror of
https://github.com/torvalds/linux.git
synced 2024-12-29 14:21:47 +00:00
nfc: mrvl: Use of_property_read_bool() for boolean properties
It is preferred to use typed property access functions (i.e. of_property_read_<type> functions) rather than low-level of_get_property/of_find_property functions for reading properties. Convert reading boolean properties to of_property_read_bool(). Reviewed-by: Simon Horman <simon.horman@corigine.com> Reviewed-by: Krzysztof Kozlowski <krzysztof.kozlowski@linaro.org> Signed-off-by: Rob Herring <robh@kernel.org> Signed-off-by: David S. Miller <davem@davemloft.net>
This commit is contained in:
parent
053fdaa841
commit
cc6d85c1cb
@ -168,7 +168,7 @@ static int nfcmrvl_i2c_parse_dt(struct device_node *node,
|
||||
return ret;
|
||||
}
|
||||
|
||||
if (of_find_property(node, "i2c-int-falling", NULL))
|
||||
if (of_property_read_bool(node, "i2c-int-falling"))
|
||||
pdata->irq_polarity = IRQF_TRIGGER_FALLING;
|
||||
else
|
||||
pdata->irq_polarity = IRQF_TRIGGER_RISING;
|
||||
|
@ -261,11 +261,7 @@ int nfcmrvl_parse_dt(struct device_node *node,
|
||||
return reset_n_io;
|
||||
}
|
||||
pdata->reset_n_io = reset_n_io;
|
||||
|
||||
if (of_find_property(node, "hci-muxed", NULL))
|
||||
pdata->hci_muxed = 1;
|
||||
else
|
||||
pdata->hci_muxed = 0;
|
||||
pdata->hci_muxed = of_property_read_bool(node, "hci-muxed");
|
||||
|
||||
return 0;
|
||||
}
|
||||
|
@ -56,16 +56,16 @@ struct nfcmrvl_platform_data {
|
||||
/* GPIO that is wired to RESET_N signal */
|
||||
int reset_n_io;
|
||||
/* Tell if transport is muxed in HCI one */
|
||||
unsigned int hci_muxed;
|
||||
bool hci_muxed;
|
||||
|
||||
/*
|
||||
* UART specific
|
||||
*/
|
||||
|
||||
/* Tell if UART needs flow control at init */
|
||||
unsigned int flow_control;
|
||||
bool flow_control;
|
||||
/* Tell if firmware supports break control for power management */
|
||||
unsigned int break_control;
|
||||
bool break_control;
|
||||
|
||||
|
||||
/*
|
||||
|
@ -76,15 +76,8 @@ static int nfcmrvl_uart_parse_dt(struct device_node *node,
|
||||
return ret;
|
||||
}
|
||||
|
||||
if (of_find_property(matched_node, "flow-control", NULL))
|
||||
pdata->flow_control = 1;
|
||||
else
|
||||
pdata->flow_control = 0;
|
||||
|
||||
if (of_find_property(matched_node, "break-control", NULL))
|
||||
pdata->break_control = 1;
|
||||
else
|
||||
pdata->break_control = 0;
|
||||
pdata->flow_control = of_property_read_bool(matched_node, "flow-control");
|
||||
pdata->break_control = of_property_read_bool(matched_node, "break-control");
|
||||
|
||||
of_node_put(matched_node);
|
||||
|
||||
|
Loading…
Reference in New Issue
Block a user