pmdomain: core: Reduce debug summary table width
Commit 9094e53ff5
("pmdomain: core: Use dev_name() instead of
kobject_get_path() in debugfs") severely shortened the names of devices
in a PM Domain. Now the most common format[1] consists of a 32-bit
unit-address (8 characters), followed by a dot and a node name (20
characters for "air-pollution-sensor" and "interrupt-controller", which
are the longest generic node names documented in the Devicetree
Specification), for a typical maximum of 29 characters.
This offers a good opportunity to reduce the table width of the debug
summary:
- Reduce the device name field width from 50 to 30 characters, which
matches the PM Domain name width,
- Reduce the large inter-column space between the "performance" and
"managed by" columns.
Visual impact:
- The "performance" column now starts at a position that is a
multiple of 16, just like the "status" and "children" columns,
- All of the "/device", "runtime status", and "managed by" columns are
now indented 4 characters more than the columns right above them,
- Everything fits in (one less than) 80 characters again ;-)
[1] Note that some device names (e.g. TI AM335x interconnect target
modules) do not follow this convention, and may be much longer, but
these didn't fit in the old 50-character column width either.
Signed-off-by: Geert Uytterhoeven <geert+renesas@glider.be>
Link: https://lore.kernel.org/r/f8e1821364b6d5d11350447c128f6d2b470f33fe.1725459707.git.geert+renesas@glider.be
Signed-off-by: Ulf Hansson <ulf.hansson@linaro.org>
This commit is contained in:
parent
2fc934190e
commit
c6ccb691d4
@ -3227,7 +3227,7 @@ static void rtpm_status_str(struct seq_file *s, struct device *dev)
|
|||||||
else
|
else
|
||||||
WARN_ON(1);
|
WARN_ON(1);
|
||||||
|
|
||||||
seq_printf(s, "%-25s ", p);
|
seq_printf(s, "%-26s ", p);
|
||||||
}
|
}
|
||||||
|
|
||||||
static void perf_status_str(struct seq_file *s, struct device *dev)
|
static void perf_status_str(struct seq_file *s, struct device *dev)
|
||||||
@ -3245,7 +3245,7 @@ static void mode_status_str(struct seq_file *s, struct device *dev)
|
|||||||
|
|
||||||
gpd_data = to_gpd_data(dev->power.subsys_data->domain_data);
|
gpd_data = to_gpd_data(dev->power.subsys_data->domain_data);
|
||||||
|
|
||||||
seq_printf(s, "%9s", gpd_data->hw_mode ? "HW" : "SW");
|
seq_printf(s, "%2s", gpd_data->hw_mode ? "HW" : "SW");
|
||||||
}
|
}
|
||||||
|
|
||||||
static int genpd_summary_one(struct seq_file *s,
|
static int genpd_summary_one(struct seq_file *s,
|
||||||
@ -3272,7 +3272,7 @@ static int genpd_summary_one(struct seq_file *s,
|
|||||||
else
|
else
|
||||||
snprintf(state, sizeof(state), "%s",
|
snprintf(state, sizeof(state), "%s",
|
||||||
status_lookup[genpd->status]);
|
status_lookup[genpd->status]);
|
||||||
seq_printf(s, "%-30s %-49s %u", genpd->name, state, genpd->performance_state);
|
seq_printf(s, "%-30s %-30s %u", genpd->name, state, genpd->performance_state);
|
||||||
|
|
||||||
/*
|
/*
|
||||||
* Modifications on the list require holding locks on both
|
* Modifications on the list require holding locks on both
|
||||||
@ -3288,7 +3288,7 @@ static int genpd_summary_one(struct seq_file *s,
|
|||||||
}
|
}
|
||||||
|
|
||||||
list_for_each_entry(pm_data, &genpd->dev_list, list_node) {
|
list_for_each_entry(pm_data, &genpd->dev_list, list_node) {
|
||||||
seq_printf(s, "\n %-50s ", dev_name(pm_data->dev));
|
seq_printf(s, "\n %-30s ", dev_name(pm_data->dev));
|
||||||
rtpm_status_str(s, pm_data->dev);
|
rtpm_status_str(s, pm_data->dev);
|
||||||
perf_status_str(s, pm_data->dev);
|
perf_status_str(s, pm_data->dev);
|
||||||
mode_status_str(s, pm_data->dev);
|
mode_status_str(s, pm_data->dev);
|
||||||
@ -3306,9 +3306,9 @@ static int summary_show(struct seq_file *s, void *data)
|
|||||||
struct generic_pm_domain *genpd;
|
struct generic_pm_domain *genpd;
|
||||||
int ret = 0;
|
int ret = 0;
|
||||||
|
|
||||||
seq_puts(s, "domain status children performance\n");
|
seq_puts(s, "domain status children performance\n");
|
||||||
seq_puts(s, " /device runtime status managed by\n");
|
seq_puts(s, " /device runtime status managed by\n");
|
||||||
seq_puts(s, "------------------------------------------------------------------------------------------------------------\n");
|
seq_puts(s, "------------------------------------------------------------------------------\n");
|
||||||
|
|
||||||
ret = mutex_lock_interruptible(&gpd_list_lock);
|
ret = mutex_lock_interruptible(&gpd_list_lock);
|
||||||
if (ret)
|
if (ret)
|
||||||
|