pmdomain: core: Reduce debug summary table width

Commit 9094e53ff5 ("pmdomain: core: Use dev_name() instead of
kobject_get_path() in debugfs") severely shortened the names of devices
in a PM Domain.  Now the most common format[1] consists of a 32-bit
unit-address (8 characters), followed by a dot and a node name (20
characters for "air-pollution-sensor" and "interrupt-controller", which
are the longest generic node names documented in the Devicetree
Specification), for a typical maximum of 29 characters.

This offers a good opportunity to reduce the table width of the debug
summary:
  - Reduce the device name field width from 50 to 30 characters, which
    matches the PM Domain name width,
  - Reduce the large inter-column space between the "performance" and
    "managed by" columns.

Visual impact:
  - The "performance" column now starts at a position that is a
    multiple of 16, just like the "status" and "children" columns,
  - All of the "/device", "runtime status", and "managed by" columns are
    now indented 4 characters more than the columns right above them,
  - Everything fits in (one less than) 80 characters again ;-)

[1] Note that some device names (e.g. TI AM335x interconnect target
    modules) do not follow this convention, and may be much longer, but
    these didn't fit in the old 50-character column width either.

Signed-off-by: Geert Uytterhoeven <geert+renesas@glider.be>
Link: https://lore.kernel.org/r/f8e1821364b6d5d11350447c128f6d2b470f33fe.1725459707.git.geert+renesas@glider.be
Signed-off-by: Ulf Hansson <ulf.hansson@linaro.org>
This commit is contained in:
Geert Uytterhoeven 2024-09-04 16:30:48 +02:00 committed by Ulf Hansson
parent 2fc934190e
commit c6ccb691d4

View File

@ -3227,7 +3227,7 @@ static void rtpm_status_str(struct seq_file *s, struct device *dev)
else else
WARN_ON(1); WARN_ON(1);
seq_printf(s, "%-25s ", p); seq_printf(s, "%-26s ", p);
} }
static void perf_status_str(struct seq_file *s, struct device *dev) static void perf_status_str(struct seq_file *s, struct device *dev)
@ -3245,7 +3245,7 @@ static void mode_status_str(struct seq_file *s, struct device *dev)
gpd_data = to_gpd_data(dev->power.subsys_data->domain_data); gpd_data = to_gpd_data(dev->power.subsys_data->domain_data);
seq_printf(s, "%9s", gpd_data->hw_mode ? "HW" : "SW"); seq_printf(s, "%2s", gpd_data->hw_mode ? "HW" : "SW");
} }
static int genpd_summary_one(struct seq_file *s, static int genpd_summary_one(struct seq_file *s,
@ -3272,7 +3272,7 @@ static int genpd_summary_one(struct seq_file *s,
else else
snprintf(state, sizeof(state), "%s", snprintf(state, sizeof(state), "%s",
status_lookup[genpd->status]); status_lookup[genpd->status]);
seq_printf(s, "%-30s %-49s %u", genpd->name, state, genpd->performance_state); seq_printf(s, "%-30s %-30s %u", genpd->name, state, genpd->performance_state);
/* /*
* Modifications on the list require holding locks on both * Modifications on the list require holding locks on both
@ -3288,7 +3288,7 @@ static int genpd_summary_one(struct seq_file *s,
} }
list_for_each_entry(pm_data, &genpd->dev_list, list_node) { list_for_each_entry(pm_data, &genpd->dev_list, list_node) {
seq_printf(s, "\n %-50s ", dev_name(pm_data->dev)); seq_printf(s, "\n %-30s ", dev_name(pm_data->dev));
rtpm_status_str(s, pm_data->dev); rtpm_status_str(s, pm_data->dev);
perf_status_str(s, pm_data->dev); perf_status_str(s, pm_data->dev);
mode_status_str(s, pm_data->dev); mode_status_str(s, pm_data->dev);
@ -3306,9 +3306,9 @@ static int summary_show(struct seq_file *s, void *data)
struct generic_pm_domain *genpd; struct generic_pm_domain *genpd;
int ret = 0; int ret = 0;
seq_puts(s, "domain status children performance\n"); seq_puts(s, "domain status children performance\n");
seq_puts(s, " /device runtime status managed by\n"); seq_puts(s, " /device runtime status managed by\n");
seq_puts(s, "------------------------------------------------------------------------------------------------------------\n"); seq_puts(s, "------------------------------------------------------------------------------\n");
ret = mutex_lock_interruptible(&gpd_list_lock); ret = mutex_lock_interruptible(&gpd_list_lock);
if (ret) if (ret)