ARM: EXYNOS: switch to using generic cpufreq driver for exynos4x12

The new CPU clock type allows the use of generic CPUfreq driver.
Switch Exynos4x12 to using generic cpufreq driver.

Previously (when exynos-cpufreq driver was used with boost
functionality) ARM_EXYNOS_CPU_FREQ_BOOST_SW config option
(which enabled boost functionality) selected EXYNOS_THERMAL
one. After switching Exynos4x12 platforms to use cpufreq-dt
driver boost support is enabled in the cpufreq-dt driver
itself (because there are turbo OPPs defined in the board's
DTS file). However we still would like to allow enabling
boost support only if thermal support is also enabled for
Exynos platforms. To achieve this make ARCH_EXYNOS config
option select THERMAL and EXYNOS_THERMAL ones.

Please also note that the switch to use the generic cpufreq-dt
driver fixes the minor issue present with the old code (support
for 'boost' mode in the exynos-cpufreq driver was enabled for
all supported SoCs even though 'boost' frequency was provided
only for Exynos4x12 ones).

Cc: Tomasz Figa <tomasz.figa@gmail.com>
Cc: Thomas Abraham <thomas.ab@samsung.com>
Cc: Javier Martinez Canillas <javier@osg.samsung.com>
Reviewed-by: Krzysztof Kozlowski <k.kozlowski@samsung.com>
Acked-by: Viresh Kumar <viresh.kumar@linaro.org>
Tested-by: Tobias Jakobi <tjakobi@math.uni-bielefeld.de>
Signed-off-by: Bartlomiej Zolnierkiewicz <b.zolnierkie@samsung.com>
Tested-by: Krzysztof Kozlowski <k.kozlowski@samsung.com>
Signed-off-by: Kukjin Kim <kgene@kernel.org>
This commit is contained in:
Bartlomiej Zolnierkiewicz 2015-08-12 07:41:11 +09:00 committed by Kukjin Kim
parent 58c036a7ac
commit bdd2648e50
2 changed files with 4 additions and 0 deletions

View File

@ -15,6 +15,7 @@ menuconfig ARCH_EXYNOS
select ARM_AMBA
select ARM_GIC
select COMMON_CLK_SAMSUNG
select EXYNOS_THERMAL
select HAVE_ARM_SCU if SMP
select HAVE_S3C2410_I2C if I2C
select HAVE_S3C2410_WATCHDOG if WATCHDOG
@ -24,6 +25,7 @@ menuconfig ARCH_EXYNOS
select PM_GENERIC_DOMAINS if PM
select S5P_DEV_MFC
select SRAM
select THERMAL
select MFD_SYSCON
help
Support for SAMSUNG EXYNOS SoCs (EXYNOS4/5)

View File

@ -227,6 +227,8 @@ static void __init exynos_init_irq(void)
static const struct of_device_id exynos_cpufreq_matches[] = {
{ .compatible = "samsung,exynos3250", .data = "cpufreq-dt" },
{ .compatible = "samsung,exynos4210", .data = "cpufreq-dt" },
{ .compatible = "samsung,exynos4212", .data = "cpufreq-dt" },
{ .compatible = "samsung,exynos4412", .data = "cpufreq-dt" },
{ .compatible = "samsung,exynos5250", .data = "cpufreq-dt" },
{ /* sentinel */ }
};