- add SPDX header; - adjust titles and chapters, adding proper markups; - mark code blocks and literals as such; - mark tables as such; - adjust identation, whitespaces and blank lines; - add to networking/index.rst. Signed-off-by: Mauro Carvalho Chehab <mchehab+huawei@kernel.org> Signed-off-by: David S. Miller <davem@davemloft.net>
This commit is contained in:
parent
20b943f075
commit
b5fcf32d7d
@ -1,26 +1,31 @@
|
||||
LINUX DRIVERS FOR BAYCOM MODEMS
|
||||
.. SPDX-License-Identifier: GPL-2.0
|
||||
|
||||
Thomas M. Sailer, HB9JNX/AE4WA, <sailer@ife.ee.ethz.ch>
|
||||
===============================
|
||||
Linux Drivers for Baycom Modems
|
||||
===============================
|
||||
|
||||
!!NEW!! (04/98) The drivers for the baycom modems have been split into
|
||||
Thomas M. Sailer, HB9JNX/AE4WA, <sailer@ife.ee.ethz.ch>
|
||||
|
||||
The drivers for the baycom modems have been split into
|
||||
separate drivers as they did not share any code, and the driver
|
||||
and device names have changed.
|
||||
|
||||
This document describes the Linux Kernel Drivers for simple Baycom style
|
||||
amateur radio modems.
|
||||
amateur radio modems.
|
||||
|
||||
The following drivers are available:
|
||||
====================================
|
||||
|
||||
baycom_ser_fdx:
|
||||
This driver supports the SER12 modems either full or half duplex.
|
||||
Its baud rate may be changed via the `baud' module parameter,
|
||||
Its baud rate may be changed via the ``baud`` module parameter,
|
||||
therefore it supports just about every bit bang modem on a
|
||||
serial port. Its devices are called bcsf0 through bcsf3.
|
||||
This is the recommended driver for SER12 type modems,
|
||||
however if you have a broken UART clone that does not have working
|
||||
delta status bits, you may try baycom_ser_hdx.
|
||||
delta status bits, you may try baycom_ser_hdx.
|
||||
|
||||
baycom_ser_hdx:
|
||||
baycom_ser_hdx:
|
||||
This is an alternative driver for SER12 type modems.
|
||||
It only supports half duplex, and only 1200 baud. Its devices
|
||||
are called bcsh0 through bcsh3. Use this driver only if baycom_ser_fdx
|
||||
@ -37,45 +42,48 @@ baycom_epp:
|
||||
|
||||
The following modems are supported:
|
||||
|
||||
ser12: This is a very simple 1200 baud AFSK modem. The modem consists only
|
||||
of a modulator/demodulator chip, usually a TI TCM3105. The computer
|
||||
is responsible for regenerating the receiver bit clock, as well as
|
||||
for handling the HDLC protocol. The modem connects to a serial port,
|
||||
hence the name. Since the serial port is not used as an async serial
|
||||
port, the kernel driver for serial ports cannot be used, and this
|
||||
driver only supports standard serial hardware (8250, 16450, 16550)
|
||||
======= ========================================================================
|
||||
ser12 This is a very simple 1200 baud AFSK modem. The modem consists only
|
||||
of a modulator/demodulator chip, usually a TI TCM3105. The computer
|
||||
is responsible for regenerating the receiver bit clock, as well as
|
||||
for handling the HDLC protocol. The modem connects to a serial port,
|
||||
hence the name. Since the serial port is not used as an async serial
|
||||
port, the kernel driver for serial ports cannot be used, and this
|
||||
driver only supports standard serial hardware (8250, 16450, 16550)
|
||||
|
||||
par96: This is a modem for 9600 baud FSK compatible to the G3RUH standard.
|
||||
The modem does all the filtering and regenerates the receiver clock.
|
||||
Data is transferred from and to the PC via a shift register.
|
||||
The shift register is filled with 16 bits and an interrupt is signalled.
|
||||
The PC then empties the shift register in a burst. This modem connects
|
||||
to the parallel port, hence the name. The modem leaves the
|
||||
implementation of the HDLC protocol and the scrambler polynomial to
|
||||
the PC.
|
||||
par96 This is a modem for 9600 baud FSK compatible to the G3RUH standard.
|
||||
The modem does all the filtering and regenerates the receiver clock.
|
||||
Data is transferred from and to the PC via a shift register.
|
||||
The shift register is filled with 16 bits and an interrupt is signalled.
|
||||
The PC then empties the shift register in a burst. This modem connects
|
||||
to the parallel port, hence the name. The modem leaves the
|
||||
implementation of the HDLC protocol and the scrambler polynomial to
|
||||
the PC.
|
||||
|
||||
picpar: This is a redesign of the par96 modem by Henning Rech, DF9IC. The modem
|
||||
is protocol compatible to par96, but uses only three low power ICs
|
||||
and can therefore be fed from the parallel port and does not require
|
||||
an additional power supply. Furthermore, it incorporates a carrier
|
||||
detect circuitry.
|
||||
picpar This is a redesign of the par96 modem by Henning Rech, DF9IC. The modem
|
||||
is protocol compatible to par96, but uses only three low power ICs
|
||||
and can therefore be fed from the parallel port and does not require
|
||||
an additional power supply. Furthermore, it incorporates a carrier
|
||||
detect circuitry.
|
||||
|
||||
EPP: This is a high-speed modem adaptor that connects to an enhanced parallel port.
|
||||
Its target audience is users working over a high speed hub (76.8kbit/s).
|
||||
|
||||
eppfpga: This is a redesign of the EPP adaptor.
|
||||
EPP This is a high-speed modem adaptor that connects to an enhanced parallel
|
||||
port.
|
||||
|
||||
Its target audience is users working over a high speed hub (76.8kbit/s).
|
||||
|
||||
eppfpga This is a redesign of the EPP adaptor.
|
||||
======= ========================================================================
|
||||
|
||||
All of the above modems only support half duplex communications. However,
|
||||
the driver supports the KISS (see below) fullduplex command. It then simply
|
||||
starts to send as soon as there's a packet to transmit and does not care
|
||||
about DCD, i.e. it starts to send even if there's someone else on the channel.
|
||||
This command is required by some implementations of the DAMA channel
|
||||
This command is required by some implementations of the DAMA channel
|
||||
access protocol.
|
||||
|
||||
|
||||
The Interface of the drivers
|
||||
============================
|
||||
|
||||
Unlike previous drivers, these drivers are no longer character devices,
|
||||
but they are now true kernel network interfaces. Installation is therefore
|
||||
@ -88,20 +96,22 @@ me for WAMPES which allows attaching a kernel network interface directly.
|
||||
|
||||
|
||||
Configuring the driver
|
||||
======================
|
||||
|
||||
Every time a driver is inserted into the kernel, it has to know which
|
||||
modems it should access at which ports. This can be done with the setbaycom
|
||||
utility. If you are only using one modem, you can also configure the
|
||||
driver from the insmod command line (or by means of an option line in
|
||||
/etc/modprobe.d/*.conf).
|
||||
``/etc/modprobe.d/*.conf``).
|
||||
|
||||
Examples::
|
||||
|
||||
Examples:
|
||||
modprobe baycom_ser_fdx mode="ser12*" iobase=0x3f8 irq=4
|
||||
sethdlc -i bcsf0 -p mode "ser12*" io 0x3f8 irq 4
|
||||
|
||||
Both lines configure the first port to drive a ser12 modem at the first
|
||||
serial port (COM1 under DOS). The * in the mode parameter instructs the driver to use
|
||||
the software DCD algorithm (see below).
|
||||
serial port (COM1 under DOS). The * in the mode parameter instructs the driver
|
||||
to use the software DCD algorithm (see below)::
|
||||
|
||||
insmod baycom_par mode="picpar" iobase=0x378
|
||||
sethdlc -i bcp0 -p mode "picpar" io 0x378
|
||||
@ -115,29 +125,33 @@ Note that both utilities interpret the values slightly differently.
|
||||
|
||||
|
||||
Hardware DCD versus Software DCD
|
||||
================================
|
||||
|
||||
To avoid collisions on the air, the driver must know when the channel is
|
||||
busy. This is the task of the DCD circuitry/software. The driver may either
|
||||
utilise a software DCD algorithm (options=1) or use a DCD signal from
|
||||
the hardware (options=0).
|
||||
|
||||
ser12: if software DCD is utilised, the radio's squelch should always be
|
||||
open. It is highly recommended to use the software DCD algorithm,
|
||||
as it is much faster than most hardware squelch circuitry. The
|
||||
disadvantage is a slightly higher load on the system.
|
||||
======= =================================================================
|
||||
ser12 if software DCD is utilised, the radio's squelch should always be
|
||||
open. It is highly recommended to use the software DCD algorithm,
|
||||
as it is much faster than most hardware squelch circuitry. The
|
||||
disadvantage is a slightly higher load on the system.
|
||||
|
||||
par96: the software DCD algorithm for this type of modem is rather poor.
|
||||
The modem simply does not provide enough information to implement
|
||||
a reasonable DCD algorithm in software. Therefore, if your radio
|
||||
feeds the DCD input of the PAR96 modem, the use of the hardware
|
||||
DCD circuitry is recommended.
|
||||
par96 the software DCD algorithm for this type of modem is rather poor.
|
||||
The modem simply does not provide enough information to implement
|
||||
a reasonable DCD algorithm in software. Therefore, if your radio
|
||||
feeds the DCD input of the PAR96 modem, the use of the hardware
|
||||
DCD circuitry is recommended.
|
||||
|
||||
picpar: the picpar modem features a builtin DCD hardware, which is highly
|
||||
recommended.
|
||||
picpar the picpar modem features a builtin DCD hardware, which is highly
|
||||
recommended.
|
||||
======= =================================================================
|
||||
|
||||
|
||||
|
||||
Compatibility with the rest of the Linux kernel
|
||||
===============================================
|
||||
|
||||
The serial driver and the baycom serial drivers compete
|
||||
for the same hardware resources. Of course only one driver can access a given
|
||||
@ -154,5 +168,7 @@ The parallel port drivers (baycom_par, baycom_epp) now use the parport subsystem
|
||||
to arbitrate the ports between different client drivers.
|
||||
|
||||
vy 73s de
|
||||
|
||||
Tom Sailer, sailer@ife.ee.ethz.ch
|
||||
|
||||
hb9jnx @ hb9w.ampr.org
|
@ -43,6 +43,7 @@ Contents:
|
||||
arcnet
|
||||
atm
|
||||
ax25
|
||||
baycom
|
||||
|
||||
.. only:: subproject and html
|
||||
|
||||
|
@ -127,7 +127,7 @@ config BAYCOM_SER_FDX
|
||||
your serial interface chip. To configure the driver, use the sethdlc
|
||||
utility available in the standard ax25 utilities package. For
|
||||
information on the modems, see <http://www.baycom.de/> and
|
||||
<file:Documentation/networking/baycom.txt>.
|
||||
<file:Documentation/networking/baycom.rst>.
|
||||
|
||||
To compile this driver as a module, choose M here: the module
|
||||
will be called baycom_ser_fdx. This is recommended.
|
||||
@ -145,7 +145,7 @@ config BAYCOM_SER_HDX
|
||||
the driver, use the sethdlc utility available in the standard ax25
|
||||
utilities package. For information on the modems, see
|
||||
<http://www.baycom.de/> and
|
||||
<file:Documentation/networking/baycom.txt>.
|
||||
<file:Documentation/networking/baycom.rst>.
|
||||
|
||||
To compile this driver as a module, choose M here: the module
|
||||
will be called baycom_ser_hdx. This is recommended.
|
||||
@ -160,7 +160,7 @@ config BAYCOM_PAR
|
||||
par96 designs. To configure the driver, use the sethdlc utility
|
||||
available in the standard ax25 utilities package. For information on
|
||||
the modems, see <http://www.baycom.de/> and the file
|
||||
<file:Documentation/networking/baycom.txt>.
|
||||
<file:Documentation/networking/baycom.rst>.
|
||||
|
||||
To compile this driver as a module, choose M here: the module
|
||||
will be called baycom_par. This is recommended.
|
||||
@ -175,7 +175,7 @@ config BAYCOM_EPP
|
||||
designs. To configure the driver, use the sethdlc utility available
|
||||
in the standard ax25 utilities package. For information on the
|
||||
modems, see <http://www.baycom.de/> and the file
|
||||
<file:Documentation/networking/baycom.txt>.
|
||||
<file:Documentation/networking/baycom.rst>.
|
||||
|
||||
To compile this driver as a module, choose M here: the module
|
||||
will be called baycom_epp. This is recommended.
|
||||
|