mirror of
https://github.com/torvalds/linux.git
synced 2024-11-16 17:12:06 +00:00
isdn/hisax: Convert pci_table entries to PCI_VDEVICE (if PCI_ANY_ID is used)
This patch converts pci_table entries, where .subvendor=PCI_ANY_ID and .subdevice=PCI_ANY_ID, .class=0 and .class_mask=0, to use the PCI_VDEVICE macro, and thus improves readability. Signed-off-by: Peter Huewe <peterhuewe@gmx.de> Signed-off-by: David S. Miller <davem@davemloft.net>
This commit is contained in:
parent
9db9f279be
commit
8f31539dfa
@ -1909,68 +1909,68 @@ static void EChannel_proc_rcv(struct hisax_d_if *d_if)
|
|||||||
|
|
||||||
static struct pci_device_id hisax_pci_tbl[] __devinitdata = {
|
static struct pci_device_id hisax_pci_tbl[] __devinitdata = {
|
||||||
#ifdef CONFIG_HISAX_FRITZPCI
|
#ifdef CONFIG_HISAX_FRITZPCI
|
||||||
{PCI_VENDOR_ID_AVM, PCI_DEVICE_ID_AVM_A1, PCI_ANY_ID, PCI_ANY_ID},
|
{PCI_VDEVICE(AVM, PCI_DEVICE_ID_AVM_A1) },
|
||||||
#endif
|
#endif
|
||||||
#ifdef CONFIG_HISAX_DIEHLDIVA
|
#ifdef CONFIG_HISAX_DIEHLDIVA
|
||||||
{PCI_VENDOR_ID_EICON, PCI_DEVICE_ID_EICON_DIVA20, PCI_ANY_ID, PCI_ANY_ID},
|
{PCI_VDEVICE(EICON, PCI_DEVICE_ID_EICON_DIVA20) },
|
||||||
{PCI_VENDOR_ID_EICON, PCI_DEVICE_ID_EICON_DIVA20_U, PCI_ANY_ID, PCI_ANY_ID},
|
{PCI_VDEVICE(EICON, PCI_DEVICE_ID_EICON_DIVA20_U) },
|
||||||
{PCI_VENDOR_ID_EICON, PCI_DEVICE_ID_EICON_DIVA201, PCI_ANY_ID, PCI_ANY_ID},
|
{PCI_VDEVICE(EICON, PCI_DEVICE_ID_EICON_DIVA201) },
|
||||||
//#########################################################################################
|
/*##########################################################################*/
|
||||||
{PCI_VENDOR_ID_EICON, PCI_DEVICE_ID_EICON_DIVA202, PCI_ANY_ID, PCI_ANY_ID},
|
{PCI_VDEVICE(EICON, PCI_DEVICE_ID_EICON_DIVA202) },
|
||||||
//#########################################################################################
|
/*##########################################################################*/
|
||||||
#endif
|
#endif
|
||||||
#ifdef CONFIG_HISAX_ELSA
|
#ifdef CONFIG_HISAX_ELSA
|
||||||
{PCI_VENDOR_ID_ELSA, PCI_DEVICE_ID_ELSA_MICROLINK, PCI_ANY_ID, PCI_ANY_ID},
|
{PCI_VDEVICE(ELSA, PCI_DEVICE_ID_ELSA_MICROLINK) },
|
||||||
{PCI_VENDOR_ID_ELSA, PCI_DEVICE_ID_ELSA_QS3000, PCI_ANY_ID, PCI_ANY_ID},
|
{PCI_VDEVICE(ELSA, PCI_DEVICE_ID_ELSA_QS3000) },
|
||||||
#endif
|
#endif
|
||||||
#ifdef CONFIG_HISAX_GAZEL
|
#ifdef CONFIG_HISAX_GAZEL
|
||||||
{PCI_VENDOR_ID_PLX, PCI_DEVICE_ID_PLX_R685, PCI_ANY_ID, PCI_ANY_ID},
|
{PCI_VDEVICE(PLX, PCI_DEVICE_ID_PLX_R685) },
|
||||||
{PCI_VENDOR_ID_PLX, PCI_DEVICE_ID_PLX_R753, PCI_ANY_ID, PCI_ANY_ID},
|
{PCI_VDEVICE(PLX, PCI_DEVICE_ID_PLX_R753) },
|
||||||
{PCI_VENDOR_ID_PLX, PCI_DEVICE_ID_PLX_DJINN_ITOO, PCI_ANY_ID, PCI_ANY_ID},
|
{PCI_VDEVICE(PLX, PCI_DEVICE_ID_PLX_DJINN_ITOO) },
|
||||||
{PCI_VENDOR_ID_PLX, PCI_DEVICE_ID_PLX_OLITEC, PCI_ANY_ID, PCI_ANY_ID},
|
{PCI_VDEVICE(PLX, PCI_DEVICE_ID_PLX_OLITEC) },
|
||||||
#endif
|
#endif
|
||||||
#ifdef CONFIG_HISAX_SCT_QUADRO
|
#ifdef CONFIG_HISAX_SCT_QUADRO
|
||||||
{PCI_VENDOR_ID_PLX, PCI_DEVICE_ID_PLX_9050, PCI_ANY_ID, PCI_ANY_ID},
|
{PCI_VDEVICE(PLX, PCI_DEVICE_ID_PLX_9050) },
|
||||||
#endif
|
#endif
|
||||||
#ifdef CONFIG_HISAX_NICCY
|
#ifdef CONFIG_HISAX_NICCY
|
||||||
{PCI_VENDOR_ID_SATSAGEM, PCI_DEVICE_ID_SATSAGEM_NICCY, PCI_ANY_ID,PCI_ANY_ID},
|
{PCI_VDEVICE(SATSAGEM, PCI_DEVICE_ID_SATSAGEM_NICCY) },
|
||||||
#endif
|
#endif
|
||||||
#ifdef CONFIG_HISAX_SEDLBAUER
|
#ifdef CONFIG_HISAX_SEDLBAUER
|
||||||
{PCI_VENDOR_ID_TIGERJET, PCI_DEVICE_ID_TIGERJET_100, PCI_ANY_ID,PCI_ANY_ID},
|
{PCI_VDEVICE(TIGERJET, PCI_DEVICE_ID_TIGERJET_100) },
|
||||||
#endif
|
#endif
|
||||||
#if defined(CONFIG_HISAX_NETJET) || defined(CONFIG_HISAX_NETJET_U)
|
#if defined(CONFIG_HISAX_NETJET) || defined(CONFIG_HISAX_NETJET_U)
|
||||||
{PCI_VENDOR_ID_TIGERJET, PCI_DEVICE_ID_TIGERJET_300, PCI_ANY_ID,PCI_ANY_ID},
|
{PCI_VDEVICE(TIGERJET, PCI_DEVICE_ID_TIGERJET_300) },
|
||||||
#endif
|
#endif
|
||||||
#if defined(CONFIG_HISAX_TELESPCI) || defined(CONFIG_HISAX_SCT_QUADRO)
|
#if defined(CONFIG_HISAX_TELESPCI) || defined(CONFIG_HISAX_SCT_QUADRO)
|
||||||
{PCI_VENDOR_ID_ZORAN, PCI_DEVICE_ID_ZORAN_36120, PCI_ANY_ID,PCI_ANY_ID},
|
{PCI_VDEVICE(ZORAN, PCI_DEVICE_ID_ZORAN_36120) },
|
||||||
#endif
|
#endif
|
||||||
#ifdef CONFIG_HISAX_W6692
|
#ifdef CONFIG_HISAX_W6692
|
||||||
{PCI_VENDOR_ID_DYNALINK, PCI_DEVICE_ID_DYNALINK_IS64PH, PCI_ANY_ID,PCI_ANY_ID},
|
{PCI_VDEVICE(DYNALINK, PCI_DEVICE_ID_DYNALINK_IS64PH) },
|
||||||
{PCI_VENDOR_ID_WINBOND2, PCI_DEVICE_ID_WINBOND2_6692, PCI_ANY_ID,PCI_ANY_ID},
|
{PCI_VDEVICE(WINBOND2, PCI_DEVICE_ID_WINBOND2_6692) },
|
||||||
#endif
|
#endif
|
||||||
#ifdef CONFIG_HISAX_HFC_PCI
|
#ifdef CONFIG_HISAX_HFC_PCI
|
||||||
{PCI_VENDOR_ID_CCD, PCI_DEVICE_ID_CCD_2BD0, PCI_ANY_ID, PCI_ANY_ID},
|
{PCI_VDEVICE(CCD, PCI_DEVICE_ID_CCD_2BD0) },
|
||||||
{PCI_VENDOR_ID_CCD, PCI_DEVICE_ID_CCD_B000, PCI_ANY_ID, PCI_ANY_ID},
|
{PCI_VDEVICE(CCD, PCI_DEVICE_ID_CCD_B000) },
|
||||||
{PCI_VENDOR_ID_CCD, PCI_DEVICE_ID_CCD_B006, PCI_ANY_ID, PCI_ANY_ID},
|
{PCI_VDEVICE(CCD, PCI_DEVICE_ID_CCD_B006) },
|
||||||
{PCI_VENDOR_ID_CCD, PCI_DEVICE_ID_CCD_B007, PCI_ANY_ID, PCI_ANY_ID},
|
{PCI_VDEVICE(CCD, PCI_DEVICE_ID_CCD_B007) },
|
||||||
{PCI_VENDOR_ID_CCD, PCI_DEVICE_ID_CCD_B008, PCI_ANY_ID, PCI_ANY_ID},
|
{PCI_VDEVICE(CCD, PCI_DEVICE_ID_CCD_B008) },
|
||||||
{PCI_VENDOR_ID_CCD, PCI_DEVICE_ID_CCD_B009, PCI_ANY_ID, PCI_ANY_ID},
|
{PCI_VDEVICE(CCD, PCI_DEVICE_ID_CCD_B009) },
|
||||||
{PCI_VENDOR_ID_CCD, PCI_DEVICE_ID_CCD_B00A, PCI_ANY_ID, PCI_ANY_ID},
|
{PCI_VDEVICE(CCD, PCI_DEVICE_ID_CCD_B00A) },
|
||||||
{PCI_VENDOR_ID_CCD, PCI_DEVICE_ID_CCD_B00B, PCI_ANY_ID, PCI_ANY_ID},
|
{PCI_VDEVICE(CCD, PCI_DEVICE_ID_CCD_B00B) },
|
||||||
{PCI_VENDOR_ID_CCD, PCI_DEVICE_ID_CCD_B00C, PCI_ANY_ID, PCI_ANY_ID},
|
{PCI_VDEVICE(CCD, PCI_DEVICE_ID_CCD_B00C) },
|
||||||
{PCI_VENDOR_ID_CCD, PCI_DEVICE_ID_CCD_B100, PCI_ANY_ID, PCI_ANY_ID},
|
{PCI_VDEVICE(CCD, PCI_DEVICE_ID_CCD_B100) },
|
||||||
{PCI_VENDOR_ID_CCD, PCI_DEVICE_ID_CCD_B700, PCI_ANY_ID, PCI_ANY_ID},
|
{PCI_VDEVICE(CCD, PCI_DEVICE_ID_CCD_B700) },
|
||||||
{PCI_VENDOR_ID_CCD, PCI_DEVICE_ID_CCD_B701, PCI_ANY_ID, PCI_ANY_ID},
|
{PCI_VDEVICE(CCD, PCI_DEVICE_ID_CCD_B701) },
|
||||||
{PCI_VENDOR_ID_ABOCOM, PCI_DEVICE_ID_ABOCOM_2BD1, PCI_ANY_ID, PCI_ANY_ID},
|
{PCI_VDEVICE(ABOCOM, PCI_DEVICE_ID_ABOCOM_2BD1) },
|
||||||
{PCI_VENDOR_ID_ASUSTEK, PCI_DEVICE_ID_ASUSTEK_0675, PCI_ANY_ID, PCI_ANY_ID},
|
{PCI_VDEVICE(ASUSTEK, PCI_DEVICE_ID_ASUSTEK_0675) },
|
||||||
{PCI_VENDOR_ID_BERKOM, PCI_DEVICE_ID_BERKOM_T_CONCEPT, PCI_ANY_ID, PCI_ANY_ID},
|
{PCI_VDEVICE(BERKOM, PCI_DEVICE_ID_BERKOM_T_CONCEPT) },
|
||||||
{PCI_VENDOR_ID_BERKOM, PCI_DEVICE_ID_BERKOM_A1T, PCI_ANY_ID, PCI_ANY_ID},
|
{PCI_VDEVICE(BERKOM, PCI_DEVICE_ID_BERKOM_A1T) },
|
||||||
{PCI_VENDOR_ID_ANIGMA, PCI_DEVICE_ID_ANIGMA_MC145575, PCI_ANY_ID, PCI_ANY_ID},
|
{PCI_VDEVICE(ANIGMA, PCI_DEVICE_ID_ANIGMA_MC145575) },
|
||||||
{PCI_VENDOR_ID_ZOLTRIX, PCI_DEVICE_ID_ZOLTRIX_2BD0, PCI_ANY_ID, PCI_ANY_ID},
|
{PCI_VDEVICE(ZOLTRIX, PCI_DEVICE_ID_ZOLTRIX_2BD0) },
|
||||||
{PCI_VENDOR_ID_DIGI, PCI_DEVICE_ID_DIGI_DF_M_IOM2_E, PCI_ANY_ID, PCI_ANY_ID},
|
{PCI_VDEVICE(DIGI, PCI_DEVICE_ID_DIGI_DF_M_IOM2_E) },
|
||||||
{PCI_VENDOR_ID_DIGI, PCI_DEVICE_ID_DIGI_DF_M_E, PCI_ANY_ID, PCI_ANY_ID},
|
{PCI_VDEVICE(DIGI, PCI_DEVICE_ID_DIGI_DF_M_E) },
|
||||||
{PCI_VENDOR_ID_DIGI, PCI_DEVICE_ID_DIGI_DF_M_IOM2_A, PCI_ANY_ID, PCI_ANY_ID},
|
{PCI_VDEVICE(DIGI, PCI_DEVICE_ID_DIGI_DF_M_IOM2_A) },
|
||||||
{PCI_VENDOR_ID_DIGI, PCI_DEVICE_ID_DIGI_DF_M_A, PCI_ANY_ID, PCI_ANY_ID},
|
{PCI_VDEVICE(DIGI, PCI_DEVICE_ID_DIGI_DF_M_A) },
|
||||||
#endif
|
#endif
|
||||||
{ } /* Terminating entry */
|
{ } /* Terminating entry */
|
||||||
};
|
};
|
||||||
|
Loading…
Reference in New Issue
Block a user