HID: wacom: Use "Confidence" flag to prevent reporting invalid contacts
The HID descriptor of many of Wacom's touch input devices include a
"Confidence" usage that signals if a particular touch collection contains
useful data. The driver does not look at this flag, however, which causes
even invalid contacts to be reported to userspace. A lucky combination of
kernel event filtering and device behavior (specifically: contact ID 0 ==
invalid, contact ID >0 == valid; and order all data so that all valid
contacts are reported before any invalid contacts) spare most devices from
any visibly-bad behavior.
The DTH-2452 is one example of an unlucky device that misbehaves. It uses
ID 0 for both the first valid contact and all invalid contacts. Because
we report both the valid and invalid contacts, the kernel reports that
contact 0 first goes down (valid) and then goes up (invalid) in every
report. This causes ~100 clicks per second simply by touching the screen.
This patch inroduces new `confidence` flag in our `hid_data` structure.
The value is initially set to `true` at the start of a report and can be
set to `false` if an invalid touch usage is seen.
Link: https://github.com/linuxwacom/input-wacom/issues/270
Fixes: f8b6a74719
("HID: wacom: generic: Support multiple tools per report")
Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com>
Tested-by: Joshua Dickens <joshua.dickens@wacom.com>
Cc: <stable@vger.kernel.org>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
This commit is contained in:
parent
304dd3680b
commit
7fb0413baa
@ -2603,6 +2603,9 @@ static void wacom_wac_finger_event(struct hid_device *hdev,
|
||||
return;
|
||||
|
||||
switch (equivalent_usage) {
|
||||
case HID_DG_CONFIDENCE:
|
||||
wacom_wac->hid_data.confidence = value;
|
||||
break;
|
||||
case HID_GD_X:
|
||||
wacom_wac->hid_data.x = value;
|
||||
break;
|
||||
@ -2635,7 +2638,8 @@ static void wacom_wac_finger_event(struct hid_device *hdev,
|
||||
}
|
||||
|
||||
if (usage->usage_index + 1 == field->report_count) {
|
||||
if (equivalent_usage == wacom_wac->hid_data.last_slot_field)
|
||||
if (equivalent_usage == wacom_wac->hid_data.last_slot_field &&
|
||||
wacom_wac->hid_data.confidence)
|
||||
wacom_wac_finger_slot(wacom_wac, wacom_wac->touch_input);
|
||||
}
|
||||
}
|
||||
@ -2653,6 +2657,8 @@ static void wacom_wac_finger_pre_report(struct hid_device *hdev,
|
||||
|
||||
wacom_wac->is_invalid_bt_frame = false;
|
||||
|
||||
hid_data->confidence = true;
|
||||
|
||||
for (i = 0; i < report->maxfield; i++) {
|
||||
struct hid_field *field = report->field[i];
|
||||
int j;
|
||||
|
@ -301,6 +301,7 @@ struct hid_data {
|
||||
bool barrelswitch;
|
||||
bool barrelswitch2;
|
||||
bool serialhi;
|
||||
bool confidence;
|
||||
int x;
|
||||
int y;
|
||||
int pressure;
|
||||
|
Loading…
Reference in New Issue
Block a user