docs: net: add an explanation of VF (and other) Representors
There's no clear explanation of what VF Representors are for, their semantics, etc., outside of vendor docs and random conference slides. Add a document explaining Representors and defining what drivers that implement them are expected to do. Signed-off-by: Edward Cree <ecree.xilinx@gmail.com> Reviewed-by: Bagas Sanjaya <bagasdotme@gmail.com> Link: https://lore.kernel.org/r/20220905135557.39233-1-ecree@xilinx.com Signed-off-by: Jakub Kicinski <kuba@kernel.org>
This commit is contained in:
parent
01bf246a20
commit
6fb4825e49
@ -92,6 +92,7 @@ Contents:
|
||||
radiotap-headers
|
||||
rds
|
||||
regulatory
|
||||
representors
|
||||
rxrpc
|
||||
sctp
|
||||
secid
|
||||
|
259
Documentation/networking/representors.rst
Normal file
259
Documentation/networking/representors.rst
Normal file
@ -0,0 +1,259 @@
|
||||
.. SPDX-License-Identifier: GPL-2.0
|
||||
|
||||
=============================
|
||||
Network Function Representors
|
||||
=============================
|
||||
|
||||
This document describes the semantics and usage of representor netdevices, as
|
||||
used to control internal switching on SmartNICs. For the closely-related port
|
||||
representors on physical (multi-port) switches, see
|
||||
:ref:`Documentation/networking/switchdev.rst <switchdev>`.
|
||||
|
||||
Motivation
|
||||
----------
|
||||
|
||||
Since the mid-2010s, network cards have started offering more complex
|
||||
virtualisation capabilities than the legacy SR-IOV approach (with its simple
|
||||
MAC/VLAN-based switching model) can support. This led to a desire to offload
|
||||
software-defined networks (such as OpenVSwitch) to these NICs to specify the
|
||||
network connectivity of each function. The resulting designs are variously
|
||||
called SmartNICs or DPUs.
|
||||
|
||||
Network function representors bring the standard Linux networking stack to
|
||||
virtual switches and IOV devices. Just as each physical port of a Linux-
|
||||
controlled switch has a separate netdev, so does each virtual port of a virtual
|
||||
switch.
|
||||
When the system boots, and before any offload is configured, all packets from
|
||||
the virtual functions appear in the networking stack of the PF via the
|
||||
representors. The PF can thus always communicate freely with the virtual
|
||||
functions.
|
||||
The PF can configure standard Linux forwarding between representors, the uplink
|
||||
or any other netdev (routing, bridging, TC classifiers).
|
||||
|
||||
Thus, a representor is both a control plane object (representing the function in
|
||||
administrative commands) and a data plane object (one end of a virtual pipe).
|
||||
As a virtual link endpoint, the representor can be configured like any other
|
||||
netdevice; in some cases (e.g. link state) the representee will follow the
|
||||
representor's configuration, while in others there are separate APIs to
|
||||
configure the representee.
|
||||
|
||||
Definitions
|
||||
-----------
|
||||
|
||||
This document uses the term "switchdev function" to refer to the PCIe function
|
||||
which has administrative control over the virtual switch on the device.
|
||||
Typically, this will be a PF, but conceivably a NIC could be configured to grant
|
||||
these administrative privileges instead to a VF or SF (subfunction).
|
||||
Depending on NIC design, a multi-port NIC might have a single switchdev function
|
||||
for the whole device or might have a separate virtual switch, and hence
|
||||
switchdev function, for each physical network port.
|
||||
If the NIC supports nested switching, there might be separate switchdev
|
||||
functions for each nested switch, in which case each switchdev function should
|
||||
only create representors for the ports on the (sub-)switch it directly
|
||||
administers.
|
||||
|
||||
A "representee" is the object that a representor represents. So for example in
|
||||
the case of a VF representor, the representee is the corresponding VF.
|
||||
|
||||
What does a representor do?
|
||||
---------------------------
|
||||
|
||||
A representor has three main roles.
|
||||
|
||||
1. It is used to configure the network connection the representee sees, e.g.
|
||||
link up/down, MTU, etc. For instance, bringing the representor
|
||||
administratively UP should cause the representee to see a link up / carrier
|
||||
on event.
|
||||
2. It provides the slow path for traffic which does not hit any offloaded
|
||||
fast-path rules in the virtual switch. Packets transmitted on the
|
||||
representor netdevice should be delivered to the representee; packets
|
||||
transmitted by the representee which fail to match any switching rule should
|
||||
be received on the representor netdevice. (That is, there is a virtual pipe
|
||||
connecting the representor to the representee, similar in concept to a veth
|
||||
pair.)
|
||||
This allows software switch implementations (such as OpenVSwitch or a Linux
|
||||
bridge) to forward packets between representees and the rest of the network.
|
||||
3. It acts as a handle by which switching rules (such as TC filters) can refer
|
||||
to the representee, allowing these rules to be offloaded.
|
||||
|
||||
The combination of 2) and 3) means that the behaviour (apart from performance)
|
||||
should be the same whether a TC filter is offloaded or not. E.g. a TC rule
|
||||
on a VF representor applies in software to packets received on that representor
|
||||
netdevice, while in hardware offload it would apply to packets transmitted by
|
||||
the representee VF. Conversely, a mirred egress redirect to a VF representor
|
||||
corresponds in hardware to delivery directly to the representee VF.
|
||||
|
||||
What functions should have a representor?
|
||||
-----------------------------------------
|
||||
|
||||
Essentially, for each virtual port on the device's internal switch, there
|
||||
should be a representor.
|
||||
Some vendors have chosen to omit representors for the uplink and the physical
|
||||
network port, which can simplify usage (the uplink netdev becomes in effect the
|
||||
physical port's representor) but does not generalise to devices with multiple
|
||||
ports or uplinks.
|
||||
|
||||
Thus, the following should all have representors:
|
||||
|
||||
- VFs belonging to the switchdev function.
|
||||
- Other PFs on the local PCIe controller, and any VFs belonging to them.
|
||||
- PFs and VFs on external PCIe controllers on the device (e.g. for any embedded
|
||||
System-on-Chip within the SmartNIC).
|
||||
- PFs and VFs with other personalities, including network block devices (such
|
||||
as a vDPA virtio-blk PF backed by remote/distributed storage), if (and only
|
||||
if) their network access is implemented through a virtual switch port. [#]_
|
||||
Note that such functions can require a representor despite the representee
|
||||
not having a netdev.
|
||||
- Subfunctions (SFs) belonging to any of the above PFs or VFs, if they have
|
||||
their own port on the switch (as opposed to using their parent PF's port).
|
||||
- Any accelerators or plugins on the device whose interface to the network is
|
||||
through a virtual switch port, even if they do not have a corresponding PCIe
|
||||
PF or VF.
|
||||
|
||||
This allows the entire switching behaviour of the NIC to be controlled through
|
||||
representor TC rules.
|
||||
|
||||
It is a common misunderstanding to conflate virtual ports with PCIe virtual
|
||||
functions or their netdevs. While in simple cases there will be a 1:1
|
||||
correspondence between VF netdevices and VF representors, more advanced device
|
||||
configurations may not follow this.
|
||||
A PCIe function which does not have network access through the internal switch
|
||||
(not even indirectly through the hardware implementation of whatever services
|
||||
the function provides) should *not* have a representor (even if it has a
|
||||
netdev).
|
||||
Such a function has no switch virtual port for the representor to configure or
|
||||
to be the other end of the virtual pipe.
|
||||
The representor represents the virtual port, not the PCIe function nor the 'end
|
||||
user' netdevice.
|
||||
|
||||
.. [#] The concept here is that a hardware IP stack in the device performs the
|
||||
translation between block DMA requests and network packets, so that only
|
||||
network packets pass through the virtual port onto the switch. The network
|
||||
access that the IP stack "sees" would then be configurable through tc rules;
|
||||
e.g. its traffic might all be wrapped in a specific VLAN or VxLAN. However,
|
||||
any needed configuration of the block device *qua* block device, not being a
|
||||
networking entity, would not be appropriate for the representor and would
|
||||
thus use some other channel such as devlink.
|
||||
Contrast this with the case of a virtio-blk implementation which forwards the
|
||||
DMA requests unchanged to another PF whose driver then initiates and
|
||||
terminates IP traffic in software; in that case the DMA traffic would *not*
|
||||
run over the virtual switch and the virtio-blk PF should thus *not* have a
|
||||
representor.
|
||||
|
||||
How are representors created?
|
||||
-----------------------------
|
||||
|
||||
The driver instance attached to the switchdev function should, for each virtual
|
||||
port on the switch, create a pure-software netdevice which has some form of
|
||||
in-kernel reference to the switchdev function's own netdevice or driver private
|
||||
data (``netdev_priv()``).
|
||||
This may be by enumerating ports at probe time, reacting dynamically to the
|
||||
creation and destruction of ports at run time, or a combination of the two.
|
||||
|
||||
The operations of the representor netdevice will generally involve acting
|
||||
through the switchdev function. For example, ``ndo_start_xmit()`` might send
|
||||
the packet through a hardware TX queue attached to the switchdev function, with
|
||||
either packet metadata or queue configuration marking it for delivery to the
|
||||
representee.
|
||||
|
||||
How are representors identified?
|
||||
--------------------------------
|
||||
|
||||
The representor netdevice should *not* directly refer to a PCIe device (e.g.
|
||||
through ``net_dev->dev.parent`` / ``SET_NETDEV_DEV()``), either of the
|
||||
representee or of the switchdev function.
|
||||
Instead, it should implement the ``ndo_get_devlink_port()`` netdevice op, which
|
||||
the kernel uses to provide the ``phys_switch_id`` and ``phys_port_name`` sysfs
|
||||
nodes. (Some legacy drivers implement ``ndo_get_port_parent_id()`` and
|
||||
``ndo_get_phys_port_name()`` directly, but this is deprecated.) See
|
||||
:ref:`Documentation/networking/devlink/devlink-port.rst <devlink_port>` for the
|
||||
details of this API.
|
||||
|
||||
It is expected that userland will use this information (e.g. through udev rules)
|
||||
to construct an appropriately informative name or alias for the netdevice. For
|
||||
instance if the switchdev function is ``eth4`` then a representor with a
|
||||
``phys_port_name`` of ``p0pf1vf2`` might be renamed ``eth4pf1vf2rep``.
|
||||
|
||||
There are as yet no established conventions for naming representors which do not
|
||||
correspond to PCIe functions (e.g. accelerators and plugins).
|
||||
|
||||
How do representors interact with TC rules?
|
||||
-------------------------------------------
|
||||
|
||||
Any TC rule on a representor applies (in software TC) to packets received by
|
||||
that representor netdevice. Thus, if the delivery part of the rule corresponds
|
||||
to another port on the virtual switch, the driver may choose to offload it to
|
||||
hardware, applying it to packets transmitted by the representee.
|
||||
|
||||
Similarly, since a TC mirred egress action targeting the representor would (in
|
||||
software) send the packet through the representor (and thus indirectly deliver
|
||||
it to the representee), hardware offload should interpret this as delivery to
|
||||
the representee.
|
||||
|
||||
As a simple example, if ``PORT_DEV`` is the physical port representor and
|
||||
``REP_DEV`` is a VF representor, the following rules::
|
||||
|
||||
tc filter add dev $REP_DEV parent ffff: protocol ipv4 flower \
|
||||
action mirred egress redirect dev $PORT_DEV
|
||||
tc filter add dev $PORT_DEV parent ffff: protocol ipv4 flower skip_sw \
|
||||
action mirred egress mirror dev $REP_DEV
|
||||
|
||||
would mean that all IPv4 packets from the VF are sent out the physical port, and
|
||||
all IPv4 packets received on the physical port are delivered to the VF in
|
||||
addition to ``PORT_DEV``. (Note that without ``skip_sw`` on the second rule,
|
||||
the VF would get two copies, as the packet reception on ``PORT_DEV`` would
|
||||
trigger the TC rule again and mirror the packet to ``REP_DEV``.)
|
||||
|
||||
On devices without separate port and uplink representors, ``PORT_DEV`` would
|
||||
instead be the switchdev function's own uplink netdevice.
|
||||
|
||||
Of course the rules can (if supported by the NIC) include packet-modifying
|
||||
actions (e.g. VLAN push/pop), which should be performed by the virtual switch.
|
||||
|
||||
Tunnel encapsulation and decapsulation are rather more complicated, as they
|
||||
involve a third netdevice (a tunnel netdev operating in metadata mode, such as
|
||||
a VxLAN device created with ``ip link add vxlan0 type vxlan external``) and
|
||||
require an IP address to be bound to the underlay device (e.g. switchdev
|
||||
function uplink netdev or port representor). TC rules such as::
|
||||
|
||||
tc filter add dev $REP_DEV parent ffff: flower \
|
||||
action tunnel_key set id $VNI src_ip $LOCAL_IP dst_ip $REMOTE_IP \
|
||||
dst_port 4789 \
|
||||
action mirred egress redirect dev vxlan0
|
||||
tc filter add dev vxlan0 parent ffff: flower enc_src_ip $REMOTE_IP \
|
||||
enc_dst_ip $LOCAL_IP enc_key_id $VNI enc_dst_port 4789 \
|
||||
action tunnel_key unset action mirred egress redirect dev $REP_DEV
|
||||
|
||||
where ``LOCAL_IP`` is an IP address bound to ``PORT_DEV``, and ``REMOTE_IP`` is
|
||||
another IP address on the same subnet, mean that packets sent by the VF should
|
||||
be VxLAN encapsulated and sent out the physical port (the driver has to deduce
|
||||
this by a route lookup of ``LOCAL_IP`` leading to ``PORT_DEV``, and also
|
||||
perform an ARP/neighbour table lookup to find the MAC addresses to use in the
|
||||
outer Ethernet frame), while UDP packets received on the physical port with UDP
|
||||
port 4789 should be parsed as VxLAN and, if their VSID matches ``$VNI``,
|
||||
decapsulated and forwarded to the VF.
|
||||
|
||||
If this all seems complicated, just remember the 'golden rule' of TC offload:
|
||||
the hardware should ensure the same final results as if the packets were
|
||||
processed through the slow path, traversed software TC (except ignoring any
|
||||
``skip_hw`` rules and applying any ``skip_sw`` rules) and were transmitted or
|
||||
received through the representor netdevices.
|
||||
|
||||
Configuring the representee's MAC
|
||||
---------------------------------
|
||||
|
||||
The representee's link state is controlled through the representor. Setting the
|
||||
representor administratively UP or DOWN should cause carrier ON or OFF at the
|
||||
representee.
|
||||
|
||||
Setting an MTU on the representor should cause that same MTU to be reported to
|
||||
the representee.
|
||||
(On hardware that allows configuring separate and distinct MTU and MRU values,
|
||||
the representor MTU should correspond to the representee's MRU and vice-versa.)
|
||||
|
||||
Currently there is no way to use the representor to set the station permanent
|
||||
MAC address of the representee; other methods available to do this include:
|
||||
|
||||
- legacy SR-IOV (``ip link set DEVICE vf NUM mac LLADDR``)
|
||||
- devlink port function (see **devlink-port(8)** and
|
||||
:ref:`Documentation/networking/devlink/devlink-port.rst <devlink_port>`)
|
@ -1,5 +1,6 @@
|
||||
.. SPDX-License-Identifier: GPL-2.0
|
||||
.. include:: <isonum.txt>
|
||||
.. _switchdev:
|
||||
|
||||
===============================================
|
||||
Ethernet switch device driver model (switchdev)
|
||||
|
Loading…
Reference in New Issue
Block a user