clk: meson: vid-pll-div: remove warning and return 0 on invalid config
The vid_pll_div is a programmable fractional divider, but vendor gives a
limited of known configuration value and it's corresponding fraction.
Thus when at reset value (0) or unknown value, we cannot determine the
result rate.
The initial behaviour was to print a warning, but the warning triggers
at each boot and when the clock tree is refreshed.
This patch moves the print to debug and returns 0 instead of the
parent rate.
Fixes: 72dbb8c94d
("clk: meson: Add vid_pll divider driver")
Signed-off-by: Neil Armstrong <narmstrong@baylibre.com>
Reviewed-by: Jerome Brunet <jbrunet@baylibre.com>
Link: https://lkml.kernel.org/r/20190327151348.27402-1-narmstrong@baylibre.com
This commit is contained in:
parent
d6f987c846
commit
6620f45ff8
@ -82,8 +82,8 @@ static unsigned long meson_vid_pll_div_recalc_rate(struct clk_hw *hw,
|
||||
div = _get_table_val(meson_parm_read(clk->map, &pll_div->val),
|
||||
meson_parm_read(clk->map, &pll_div->sel));
|
||||
if (!div || !div->divider) {
|
||||
pr_info("%s: Invalid config value for vid_pll_div\n", __func__);
|
||||
return parent_rate;
|
||||
pr_debug("%s: Invalid config value for vid_pll_div\n", __func__);
|
||||
return 0;
|
||||
}
|
||||
|
||||
return DIV_ROUND_UP_ULL(parent_rate * div->multiplier, div->divider);
|
||||
|