mirror of
https://github.com/torvalds/linux.git
synced 2024-11-10 14:11:52 +00:00
Fix loop device flush before configure v3
While installing SLES-12 (based on v4.4), I found that the installer will stall for 60+ seconds during LVM disk scan. The root cause was determined to be the removal of a bound device check in loop_flush() by commitb5dd2f6047
("block: loop: improve performance via blk-mq"). Restoring this check, examining ->lo_state as set by loop_set_fd() eliminates the bad behavior. Test method: modprobe loop max_loop=64 dd if=/dev/zero of=disk bs=512 count=200K for((i=0;i<4;i++))do losetup -f disk; done mkfs.ext4 -F /dev/loop0 for((i=0;i<4;i++))do mkdir t$i; mount /dev/loop$i t$i;done for f in `ls /dev/loop[0-9]*|sort`; do \ echo $f; dd if=$f of=/dev/null bs=512 count=1; \ done Test output: stock patched /dev/loop0 18.1217e-05 8.3842e-05 /dev/loop1 6.1114e-05 0.000147979 /dev/loop10 0.414701 0.000116564 /dev/loop11 0.7474 6.7942e-05 /dev/loop12 0.747986 8.9082e-05 /dev/loop13 0.746532 7.4799e-05 /dev/loop14 0.480041 9.3926e-05 /dev/loop15 1.26453 7.2522e-05 Note that from loop10 onward, the device is not mounted, yet the stock kernel consumes several orders of magnitude more wall time than it does for a mounted device. (Thanks for Mike Galbraith <efault@gmx.de>, give a changelog review.) Reviewed-by: Hannes Reinecke <hare@suse.com> Reviewed-by: Ming Lei <ming.lei@redhat.com> Signed-off-by: James Wang <jnwang@suse.com> Fixes:b5dd2f6047
("block: loop: improve performance via blk-mq") Signed-off-by: Jens Axboe <axboe@fb.com>
This commit is contained in:
parent
6679a90c4b
commit
6460495709
@ -608,6 +608,9 @@ static int loop_switch(struct loop_device *lo, struct file *file)
|
||||
*/
|
||||
static int loop_flush(struct loop_device *lo)
|
||||
{
|
||||
/* loop not yet configured, no running thread, nothing to flush */
|
||||
if (lo->lo_state != Lo_bound)
|
||||
return 0;
|
||||
return loop_switch(lo, NULL);
|
||||
}
|
||||
|
||||
|