pwm: lp3943: Fix duty calculation in case period was clamped
The hardware only supports periods <= 1.6 ms and if a bigger period is
requested it is clamped to 1.6 ms. In this case duty_cycle might be bigger
than 1.6 ms and then the duty cycle register is written with a value
bigger than LP3943_MAX_DUTY. So clamp duty_cycle accordingly.
Fixes: af66b3c093
("pwm: Add LP3943 PWM driver")
Signed-off-by: Uwe Kleine-König <u.kleine-koenig@pengutronix.de>
Signed-off-by: Thierry Reding <thierry.reding@gmail.com>
This commit is contained in:
parent
b3c4af8507
commit
5e3b07ca5c
@ -125,6 +125,7 @@ static int lp3943_pwm_config(struct pwm_chip *chip, struct pwm_device *pwm,
|
||||
if (err)
|
||||
return err;
|
||||
|
||||
duty_ns = min(duty_ns, period_ns);
|
||||
val = (u8)(duty_ns * LP3943_MAX_DUTY / period_ns);
|
||||
|
||||
return lp3943_write_byte(lp3943, reg_duty, val);
|
||||
|