drm/amd/display: Do 1-to-1 mapping between OPP and DSC in DML2
[why] To determine which block instance to power-gate, we look at the available pipe resource for both plane and stream. On MPO, DSC3 was falsely powered on even though only 1 stream path was enabled because the resource mapping was not done correctly. [how] Acquire the correct DSC instance to power on / off based on the instance of OPP which determines the backend pipe index. Reviewed-by: Swapnil Patel <swapnil.patel@amd.com> Signed-off-by: Jerry Zuo <jerry.zuo@amd.com> Signed-off-by: Sung Joon Kim <sungjoon.kim@amd.com> Tested-by: Daniel Wheeler <daniel.wheeler@amd.com> Signed-off-by: Alex Deucher <alexander.deucher@amd.com>
This commit is contained in:
parent
906fd46a65
commit
5d2c102def
|
@ -5166,7 +5166,7 @@ bool dc_resource_acquire_secondary_pipe_for_mpc_odm_legacy(
|
|||
sec_pipe->stream_res.opp = sec_pipe->top_pipe->stream_res.opp;
|
||||
if (sec_pipe->stream->timing.flags.DSC == 1) {
|
||||
#if defined(CONFIG_DRM_AMD_DC_FP)
|
||||
dcn20_acquire_dsc(dc, &state->res_ctx, &sec_pipe->stream_res.dsc, pipe_idx);
|
||||
dcn20_acquire_dsc(dc, &state->res_ctx, &sec_pipe->stream_res.dsc, sec_pipe->stream_res.opp->inst);
|
||||
#endif
|
||||
ASSERT(sec_pipe->stream_res.dsc);
|
||||
if (sec_pipe->stream_res.dsc == NULL)
|
||||
|
|